5.3 Temperature Protection System (TPS)

DynaScan’s products have a system of temperature protection to implement some

procedures in order to extend their lifetime. If the sensors inside DynaScan’s products

detect the temperature out of the rang from 5

to 35

when starting, they will take some

actions to protect the products. The following table shows the status and actions for

different protection.

Timing

Status

Action

Release Condition

Start

<5

Pre-heating(All white, motor still)

>5

or

10 min later

Start

>35

Pre-cooling(No display, motor running)

<35

or

5 min later

Operating

>60

Cooling(No display, motor running)

<50

Shut

down

--

Cooling(No display, motor running for 6
min)

6 min later