3 temperature protection system (tps) – DynaScan Outdoor 360 Degree LED Video Display DS1713 User Manual
Page 24
Copyright
©
2007-2013 DynaScan Technology Corp. 18
5.3 Temperature Protection System (TPS)
DynaScan’s products have a system of temperature protection to implement some
procedures in order to extend their lifetime. If the sensors inside DynaScan’s products
detect the temperature out of the rang from 5
℃
to 35
℃
when starting, they will take some
actions to protect the products. The following table shows the status and actions for
different protection.
Timing
Status
Action
Release Condition
Start
<5
℃
Pre-heating(All white, motor still)
>5
℃
or
10 min later
Start
>35
℃
Pre-cooling(No display, motor running)
<35
℃
or
5 min later
Operating
>60
℃
Cooling(No display, motor running)
<50
℃
Shut
down
--
Cooling(No display, motor running for 6
min)
6 min later