The display’s bottom is a hexangular compartment. Of the six sides, five serve

ventilation purposes as indicated above. When you lay out the lower decoration

for the base, the six sides must be separated completely and sealed completely

from the others to prevent the cool and the hot air from mixing and take in the

base again.

The vent of the decoration located around the hot air exhaust on the bottom of

the display body should be able to vent the minimum airflow rate of 25.0 M

3

/min

(about 880 CFM).

The part of the decoration located opposite to the cool air in-flow vent should

leave a minimum air intake of 0.35 M

2

.

If you prefer not to or unable to install heat dissipation fans on the decoration,

please at least leave a 0.35 M

2

ventilation at each side of the

hexangular base.