beautypg.com

Rugged, reliable, mobile, secure – CRU DE75 ATA/133 User Manual

Page 2

background image

Rugged, Reliable, Mobile, Secure

TM

1-800-260-9800

www.CRU-DataPort.com

Note: The lock on the Data Express serves as a power

switch. It must be engaged (turned counterclockwise) for the

Data Express to power up and function properly.

Limited Product Warranty

CRU-DataPort (CRU) warrants the Data Express DE75 to be free

of significant defects in material and workmanship for a period of

five years from the original date of purchase. CRU’s warranty is

nontransferable and is limited to the original purchaser.

Limitation of Liability

The warranties set forth in this agreement replace all other war-

ranties. CRU expressly disclaims all other warranties, including but

not limited to, the implied warranties of merchantability and fit-

ness for a particular purpose and non-infringement of third-party

rights with respect to the documentation and hardware. No CRU

dealer, agent or employee is authorized to make any modifica-

tion, extension, or addition to this warranty. In no event will CRU

or its suppliers be liable for any costs of procurement of substi-

tute products or services, lost profits, loss of information or data,

computer malfunction, or any other special, indirect, consequen-

tial, or incidental damages arising in any way out of the sale of,

use of, or inability to use any CRU product or service, even if CRU

has been advised of the possibility of such damages. In no case

shall CRU’s liability exceed the actual money paid for the products

at issue. CRU reserves the right to make modifications and addi-

tions to this product without notice or taking on additional liability.

Certification

EMI Standard: FCC Part 15 Class B, CE

EMC Standard: EN55022, EN55024

FCC Certification

This device has been tested and found to comply with the

limits for a Class B digital device, pursuant to Part 15 of the

FCC rules. Operation is subject to the following two condi-

tions:

1. This device may not cause harmful interference.

2. This device must accept any interference received; includ-

ing interference that may cause undesired operation.

Register your product at www.CRU-DataPort.com

A7-075-0004 Rev. 2.1

However, the appropriate jumper setting must still be configured

on JP6 (ID0 & ID1) located on the receiving frame motherboard

(Figure 2). For Master setting, install jumper on ID0 (Pins 1 & 2).

For slave setting, install jumper on ID1 (Pins 3 & 4).

Skip the Method 2 section and continue with installation.

Method 2

Using the hard-wire connector JP3 on the drive carrier circuit

board to allow drive carrier interchangeability between Master/

Slave configured receiving frames

To allow this interchangeability it is necessary to set the Mas-

ter/Slave drive selection by a hard-wire connection between the

drive and the drive carrier circuit board.

This method requires the fabrication of a cable wire (not pro-

vided). Refer to the DE75i-A100 Manual for further information

regarding Method 2.

Unit ID Select Switch Settings

The following table lists the unit ID select switch settings and the

valid AT/IDE unit numbers. Invalid switch settings are indicated by an

“X” and will result in a blank display in the receiving frame window.

Unit ID Select Switch Settings

Note: The unit ID number display is for ID display purposes

only. The master/slave setting must still be set on the drive

itself (refer to the drive manufacturer’s documentation for

further information).

Selecting the Unit ID Number: Use the alignment tool (pro-

vided) to select the ID number of the disk drive.

Unit ID Select

Switch Location

Unit ID

Select Switch

Alignment Tool