CIRCUTOR T3V Series User Manual
Page 3

--------- EARTH RESISTANCE TESTER
T-3V
------- Page No. 2
-
1.- GENERAL REMARKS
NOTE:
This tester has been designed and checked in accordance with
IEC Publication 348, safety requirements for electronic measuring equipment, IEC
61268-1010 (EN61010) and other safety standards. Please follow all advice to
ensure safe operation.
1.1.- Description
Some of the most important features of the the T-3V are:
Ability to measure earth voltage.
The 2 mA measurement current allows floor resistivity to be tested
without tripping the earth circuit breakers in the circuit to be checked.
Battery
operation.
Self-disconnecting. The timer automatically operates after 3~6 minutes
without operating any check. When the operating button and the timer
activator are pressed at the same time, the measurer is kept operating.
Memory reading function.
Open circuit indicator. The OFF LED indicates when the connection for
the test points is correct.
Compact and light.
Designed to meet safety standard IEC-1010 (EN61010).