Bytes 8 to 11 – Casella CEL CEL-296 User Manual
Page 53

Where:
RR = Bandwidth switch
00
= All pass
01 =
Octave
10
= 1/3 Octave
11
= 1/18 Octave (with suitable Filter Sets)
BC = Band change
The current pass band has been reset
during the last 0.5 s
P =
Playback
0
= Normal mode
1
= CEL-296 Recalling stored data
B
= Battery low
1
= Battery voltage less than 3.2 V
V
= Overload function
1
= Overload indicated
X
= Not allocated, so normally 0
Bytes 8 to 11
These bytes are used to indicate the chosen filter band centre
frequency.
BIT
7 6 5 4 3 2 1 0
0 X X X X X X X
CEL-296 in Normal mode "DDD " or "ALL "
CEL-296 in Recall mode 'DDDS" or "ALLS"
CEL-288 has 4 digits "DDDD" or "ALL "
Where: D = ASCII character identifying the frequency
band
“ “
= ASCII space character
CEL Instruments Ltd
CEL-296/3 Operator Handbook
Page 53