Programmable Outputs on the IN/OUT 2 Connector
The IN/OUT 2 connector provides four additional
programmable outputs, OUT1 - OUT4.
The outputs can be used to drive LEDs, relays and
the inputs of other electronic devices like PLCs and
counters. The “+” (collector) and “-” (emitter) termi-
nals of each phototransistor are available at the con-
nector. This allows you to configure each output for
current sourcing or sinking.
Diagrams for various connections follow.
Do not connect the outputs to more than 30VDC.
The current through each output terminal must not
exceed 100 mA.
PLC
BLu-QE/SE
12-24 VDC
Power Supply
+
–
OUT-
OUT+
IN
COM
Connecting an IN/OUT 2 output to a PLC
BLu Servo
YCOM
OUT+
5-24 VDC
Power Supply
+
–
Load
Sinking (High Side) Load
inside IN/OUT 2
OUT1+
OUT1-
OUT2+
OUT2-
OUT3+
OUT3-
OUT4+
OUT4-
20
19
18
22
21
24
25
23