33 bluac5 s/q hardware manual, Blu-qe/se gnd ain +5 – Applied Motion BLuAC5-Q User Manual
Page 33

33
BLuAC5 S/Q Hardware manual
920-0049 Rev. C
12/8/2014
Connecting to the Analog Input on the IN/OUT 2 Connector
The analog input on the IN/OUT 2 connector can be used by “Feed to Sensor” commands
and other input functions when operating the drive in “Host” mode. The analog input can also
be read back to the “Host” using the “IA3” immediate command. Readings are in Volts. See
“BLu Servo Host Command Reference” for more information.
+5 volt DC is provided for powering potentiometers. A 1000 to 10000 ohm potentiometer is
recommended and should be connected as shown below.
A 0 to 5 volt analog signal may also be used. Usually this signal comes from a PLC, a PC
with data acquisition card or a motion controller. Connections are shown below.
The +5V terminal is an output. Do not connect it to a power supply.
Connecting the Analog Input to a Potentiometer
0 - 5V
speed signal
signal return
BLU-QE/SE
GND
AIN
1-10k
W
pot
cw
ccw
BLU-QE/SE
GND
AIN
+5
Connecting the Analog Input to an Active Signal