Connecting limit switches – Applied Motion ST10-C-CE User Manual
Page 31

31
ST5/10-Si,-Q,-C, IP Hardware manual
920-0004 Rev. F
6/10/14
Connecting a PNP Type Proximity Sensor to a an input
(When prox sensor activates, input goes low).
DRIVE
PNP
Proximity
Sensor
X3..X6
output
+
–
XCOM
12-24
VDC
Power
Supply
-
+
Connecting Limit Switches
The CWLIMIT and CCWLIMIT inputs are used for connecting end of travel sensors. These inputs
are differential, which allows you to use signals that are sinking (NPN), sourcing (PNP) or differen-
tial (line driver). By connecting switches or sensors that are triggered by the motion of the motor
or load, you can force the motor to operate within certain limits. This is useful if a program or
operator error could cause damage to your system by traveling too far.
The limit inputs are optically isolated. This allows you to choose a voltage for your limit circuits of
12 to 24 volts DC. This also allows you to have long wires on limit sensors that may be far from
the drive with less risk of introducing noise to the drive electronics. The schematic diagram of the
limit switch input circuit is shown below.
inside drive
2200
X8/CCWLIM-
25
X8/CCWLIM+
24
2200
X7/CWLIM-
23
X7/CWLIM+
22