FORM NO. L-20071-R-1211

Symptom

Probable Cause

Solution

Failure to

engage

Low or lack of air pressure

Replace the control valve.

Internal contamination or corrosion

Align the exhaust port to the six o'clock
down position to allow condensation to drain
out of the exhaust port.

Failure to

disengage

Broken Compression Springs

Replace the Compression Springs.

Air not being exhausted due to a control
valve malfunction

Check for control valve malfunction and
replace it if necessary.

Check for air leaks in the air lines and
around the O-rings Seals. Replace the air
lines or O-ring Seals if necessary.

Internal contamination or corrosion

Align the exhaust port to the six o'clock
down position to allow condensation to drain
out of the exhaust port.

Loss of torque

Worn or dirty Friction Facings

Replace the Friction Facings.

TROUBLESHOOTING

BRAKE ASSEMBLY

FIGURE 4

Friction

Facing

Piston

Plate

Shoulder

Bolt

Compression

Spring

Ball

Bearing

O-ring

Seals

Air

Chamber

Piston

Friction

Disc Hub