SINGLE AIR PRESSURE CONTROL SYSTEM

Nexen’s Single Air Pressure Control System consists of:

Constant Bleed Type Regulator, Gauge, Quick Exhaust

Shuttle Valve, Tee Fitting , 3-Way N.C. (Normally Closed)

Solenoid Valve, and Air Line.

AIR CONNECTIONS

NOTE: Nexen recommends using a Constant Bleed Air

Regulator along with a 3-Way Solenoid Valve to ensure

a total "crisp" release when overload conditions arise.

ELECTRICAL CONNECTIONS

PLC

Valve

Torque

Limiter

Prox.

Sensor

Nexen Supplied

Torque

Limiter

Prox.

Sensor

Valve

Relay

Nexen Supplied

NOTE: Scan time for PLC on proximity sensor should not exceed 0.07 seconds.

Proximity Sensor Wiring Schematic

FIGURE 4

FIGURE 3

BU

L2

L1

BN

LOAD

Voltage

20–250 VAC,

10–300 VDC

Line Frequency

40–60 Hz

Voltage Drop Across

Conducting Sensor

<6.0 V at 100 mA

Continuous Load Current

<100 mA

Off-State (Leakage) Current

<1.7 mA

Minimum Load Current

3.0 mA

Maximum Inrush Current

1.0 A (<30 ms, 15% Duty

Cycle)

PROXIMITY SENSOR SPECIFICATIONS

CAUTION

Do not use rigid pipe and tubing when making

air line connections. Torque on the air line

caused by bearing drag may be relieved by

resting the air line on a support parallel to the

torque limiter center-line. Align the air inlet

port to the six o'clock down position to allow

condensation in the air chamber to drain out

of the exhaust port.

The supplied Proximity Sensor is shown operating in two

typical scenarios in Figure 3. It is the responsibility of

the system integrator to ensure the limits of the Proximity

Sensor Specifications are followed for integration into a

robust system. See Figure 4 for Proximity Sensor Wiring

Schematic, and Table 3 for Electrical Specifications.

TABLE 3

All Nexen pneumatically actuated devices require clean

and dry air, which meet or exceeds ISO 8573.1:2001

Class 4.4.3 quality.

The following is a common air supply scheme used with

this product. This is an example and not an all-inclusive

list. All air circuits to be used with this product must be

designed following EN983 guidelines.

NOTE

For quick response, Nexen recommends a quick exhaust

valve and short air lines between the Control Valves and

the unit. Align the air inlet ports to a down position to

allow condensation to drain out of the air

chambers of the product.