beautypg.com

Warning, Caution – Nexen TL50A/4-E 803017 User Manual

Page 11

background image

11

FORM NO. L-21174-E-1209

Refer to Figures 7 & 8.

1. Shut off machine and air supply to the Torque Limiter.

2. Disconnect the Torque Limiter from the air supply by

removing the Quick Exhaust Shuttle Valve and the
3-Way N.C. Solenoid Valve.

3. Remove the Torque Limiter from the machine.

Drive Flange

Assembly

(Item 19)

Cylinder/Piston

Assembly

(Items 8 and 9)

Cylinder/Piston

Assembly

(Items 8 and 9)

Hub

(Item 7)

Rotary Seal

(Item 15)

Retaining Ring

(Item 6)

Retaining Ring

(Item 6)

FIGURE 7

FIGURE 8

4. Remove the Retaining Ring (Item 6) from the Hub (Item

7) on the Drive Flange Assembly (Item 19) end of the
Torque Limiter.

5. Supporting Drive Flange Assembly (Item 19), press

Hub (Item 7) and Cylinder/Piston Assembly out of the
Drive Flange.

6. Remove the Rotary Seal (Item 15) from the Drive Flange

Assembly.

NOTE: Rotary seal style/location has changed (except

for in TL20A-E models). If Torque Limiter has old rotary

seal design, seal is located in the Cylinder/Piston

Assembly (Items 8 & 9). Refer to Table 6 and Figure 6 to

determine what style rotary seal is used on your product.

All other procedures are identical between models.

7. Remove Retaining Ring (Item 6) from the Hub (Item 7)

on the Cylinder/Piston end of Torque Limiter.

8. Supporting the Cylinder/Piston Assembly, press the

Hub (Item 7) out of the Cylinder/Piston Assembly.

PARTS REPLACEMENT

TORQUE LIMITER REMOVAL AND DISASSEMBLY

CAUTION

Correct alignment of Torque Limiter internal

components is critical for proper operation

of the Torque Limiter. Before disassembly,

mark Hub, Cylinder, and Drive Flange with

chalk alignment marks to ensure correct

alignment of internal components when

reassembling Torque Limiter.

WARNING

Special attention should be exercised

when working with retaining rings.

Always wear safety goggles when

working with spring or tension loaded

fasteners or devices.