beautypg.com

Diagnostics, 1 signal outputs for status information, 7operation – Pilz PIT m3.1p User Manual

Page 35: 6 diagnostics

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

7-7

7.6

Diagnostics

7

Operation

7.6

Diagnostics

7600

Diagnostics

7-

Diagnose BAWS

For monitoring and diagnostics of the operating mode selector switch

4 back-lit buttons and 4 signal outputs are available. The outputs report

status information, which is divided into the following information class-

es:

Selected operating mode

Set authorisation

Messages (e.g. user error and fault)

The status information can be evaluated through a control system.

The back-lit buttons indicate the operating mode selected on the oper-

ating mode selector switch.

7.6.1

Signal outputs for status information

Signal outputs for status information

7-

Meldeausgänge Statusinformation BAWS

The status information indicates the actions performed by the operator.

These actions are: actuator connected, actuator removed and operating

mode selected.

NOTICE

If OM is selected (SI3:0=8h ... Bh) information remains active

indefinitely. All other information stays active for just 200 ms.

After that time the selected operating mode is again displayed.

Status information

SI 3 (MSB)

SI 2

SI 1

SI 0 (LSB)

SI3:0= [hex]

Reserve

0

0

0

0

0h

Reserve

0

0

0

1

1h

Reserve

0

0

1

0

2h

Reserve

0

0

1

1

3h

Key Mode 1 - connected

0

1

0

0

4h

Key Mode 2 - connected

0

1

0

1

5h

Key Mode 3 - connected

0

1

1

0

6h

Key Mode 4 - connected

0

1

1

1

7h

OM1 selected

1

0

0

0

8h

OM2 selected

1

0

0

1

9h

OM3 selected

1

0

1

0

Ah

OM4 selected

1

0

1

1

Bh

No authorisation

1

1

0

0

Ch