Time monitoring
7
Operation
7.2
Time monitoring
7200
Time monitoring
7-
Zeitüberwachung BAWS
A change of operating modes is only detected once a button has been
operated for a certain time period.
Operating time:
OM1, OM2, OM3, OM4: > 50 ms and < 5 s
Special mode (service) OM5: > 5 s and < 10 s
When a button is released, the semiconductor outputs will switch once
the switchover delay t1 has elapsed (see Technical details).
When changing operating modes, the PIT m3.1p initiates a defined
pause of 50 ms to guarantee that the operating modes do not overlap.
To select an operating mode, follow the instructions below:
Select an operating mode by pressing one of the four buttons. The ac-
tuator must be connected to the operating mode selector switch for the
whole time the button is operated; it can be removed afterwards.