Wiring, Terminal configuration, 6wiring – Pilz PIT m3.1p User Manual

Page 25: 1 terminal configuration

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-1

6.1

Terminal Configuration

6

Wiring

6

6000

Wiring

Wiring

6-

6.1

Terminal Configuration

6100

Terminal Configuration

6-

Klemmenbelegung BAWS

Connect the supply voltage X1 (A1/A2). The power supply must meet

the regulations for extra low voltages with safe separation (SELV,

PELV).

Connect the semiconductor outputs X1 (OM1 ... OM5) to a safety sys-

tem that supports a safe 1 from n evaluation.

Connect the signal outputs X2 (SI0 ... SI3) to a control system that

supports evaluation of the status information.

Connect the interface X2 (signal outputs IDsync, IDclock, IDo0, IDo1

and inputs IDi0 and IDi1) to a control system that supports the down-

load of the Key ID number.

Functional earth connection.

INFORMATION

The connection terminals are not supplied with the unit.