HERITAGE

®

VINTAGE

®

LAMINATED ASPHALT SHINGLES
Phillipsburg, KS

2

the shingle making certain nails are covered by the next (successive)

course of shingles. Each shingle tab must be sealed underneath

with TAM-PRO® SBS Flashing Cement, TAMKO or TAM-PRO®

Plastic Roof Cement, or TAMKO Tam-Seal Adhesive immediately

upon installation. Quarter-sized dabs of cement or adhesive must be

applied to shingles with a 5 in. exposure, use 9 fasteners per shingle.

(See Mansard Fastening Pattern illustrated below).

MANSARD FASTENING PATTERN

3) High Wind Warranty Fastening Pattern. (For High Wind Warranty

Application requirements) One fastener 1-1/2" from each end. One

fastener 8-7/8" from each end and one fastener 16-1/4" from each

end for a total of six (6) fasteners per shingle. In addition to this shingle

fastening pattern requirement for High Wind Application, TAMKO also

requires the use of TAMKO starter shingles including sealant strip at

eaves and rakes. Alternatively, along rakes, cement shingles to the

underlayment and each other in a 4 in. (102 mm) width of TAM-PRO®

SBS Flashing Cement, TAMKO or TAM-PRO® Plastic Roof Cement,

or TAMKO Tam-Seal Adhesive. Caution: Apply ONLY a thin uniform

layer of adhesive less than 1/8 in. (3mm) thick. Excessive amounts can

cause blistering of the shingles and may soften the asphalt in certain

underlayments resulting in the asphalt flowing, dripping and staining.

High Wind Application is offered on new construction or complete

tear-off applications only. It is not offered for recover applications. If

High Wind Application requirements are not followed, the High Wind

Application Warranty MPH, as stated on Table I in the Limited Warranty,

reverts to the Standard Application Wind Warranty MPH limit. (See

High Wind Fastening Pattern illustrated below.)

HIGH WIND WARRANTY FASTENING PATTERN

NAILS: TAMKO recommends the use of nails as the preferred method

of application. Standard type roofing nails should be used. Nail

shanks should be made of minimum 12 gauge wire, and a minimum

head diameter of 3/8 in. Nails should be long enough to penetrate

3/4 in. into the roof deck. Where the deck is less than 3/4 in. thick,

the nails should be long enough to penetrate completely through

plywood decking and extend at least 1/8 in. through the roof deck.

Drive nail head flush with the shingle surface.

Fasteners

6“

5“

Exposure

Nail

Zone

6“

Apply under each tab 1“ diameter asphalt adhesive cement.

N

ot

ch 2

N

ot

ch 1

Alignment

Notches

40“

(CONTINUED from page 1)

(Continued)

Properly Driven

3/8” min diameter

underdriven

overdriven

Improperly Driven

crooked

Asphalt

Shingles

Decking

inadequate

anchorage

too deep, cuts

into shingle

inadequate

penetration

straight, good penetration,

and flush with shingle surface

1/4” nominal

1/2”

3/4” min

4. UNDERLAYMENT
UNDERLAYMENT:
An underlayment must be applied over the
entire deck before the installation of TAMKO shingles. Failure to add
underlayment can cause premature failure of the shingles which is
not covered by TAMKO’s Limited Warranty.

Products which are acceptable for use as underlayment are:

Asphalt Saturated Felt Underlayments:

• SuperX 30™ Underlayment
• TAMKO No. 15 Asphalt Saturated Organic Felt
• Any TAMKO non-perforated asphalt saturated organic felt
• A non-perforated asphalt saturated organic felt which meets

ASTM: D226, Type I or II or ASTM D4869

Specialty Underlayments:

• Tam-Shield® Synthetic Underlayment or Synthetic Shield

Underlayment

• TAMKO TW Metal and Tile Underlayment, TW Underlayment

and Moisture Guard Plus® (additional ventilation may be
required. Contact TAMKO’s Technical Services Department
for more information.)

• A self-adhesive underlayment designed for use with asphalt

shingles which meets ASTM D1970.

For Asphalt Saturated Felt Underlayments:

Apply the felt when the deck is dry. On roof decks with slopes
4 in. per foot and greater apply the felt parallel to the eaves
lapping each course of the felt over the lower course at least
2 in. Where ends join, lap the felt 4 in. If left exposed, the felt
may be adversely affected by moisture and weathering. Laying
of the felt and the shingle application must be done together.

For All Other Specialty Underlayments:

On roof decks with slopes 4 in. per foot and greater apply
the underlayment parallel to the eaves in accordance
with underlayment written application instructions. The
underlayment should not be left exposed for a longer period of
time than is specified in the underlayments written application
instructions. The final roof covering must be installed before
the structure is exposed to adverse weather conditions, such
as wind driven rain, high wind, hail, ice storms, etc.

In areas where ice builds up along the eaves or a back-up of water
from frozen or clogged gutters is a potential problem, TAMKO’s
Moisture Guard Plus

®

, TW Metal and Tile Underlayment or TW

Underlayment (or any specialty eaves flashing product) may be
applied to eaves, rakes, ridges, valleys, around chimneys, skylights
or dormers to help prevent water damage. Contact TAMKO’s
Technical Services Department for more information.

Substitute products as shingle underlayment should not be used.