Application instructions for

STEP 4

Install insulated female

terminal from thermostat

to male terminal on motor.

STEP 5

Tape or wire tie wires to motor

mounting bracket to prevent

contact with fan blade.

MOTOR

THERMOSTAT

STEP 3

Remove existing

RED wire terminal

from motor and

connect it to

insulated male

terminal from

thermostat.

STEP 1

Cover solar panel with cardboard taping it to the unit to prevent motor from running.
STEP 2

When installing thermostat to Surface, Remote and Curb Mount models that have

already been installed onto roof, separate the ventilator dome from the base by

removing the four (4) 5/16" stainless steel sheet metal screws. Lift the ventilator

dome off the ventilator base and proceed with the following steps.

STEP 6

(if required) Re-attach the ventilator dome to the ventilator base using the

four (4) stainless steel 5/16" sheet metal screws removed in Step 2.
STEP 7

Remove cardboard from the solar panel and verify that the ventilator operates.