beautypg.com

Stan, Cool, Econ – Dynasty Spas Deluxe System D-1000 User Manual

Page 18

background image

If the high limit sensor detects 40 F at the heater, then the pumps

and blower (if installed) automatically activates to provide freeze

protection. The equipment stays on until the sensor detects 45 F at the

heater. Freeze protection is activated regardless of the spa's status.

In colder climates, an optional additional freeze sensor may be added

to protect against freeze conditions. See your dealer for details.

OH

StAn

S

n

1

Overheat Protection (Spa is deactivated)

DO NOT ENTER THE WATER. If the spa water has reached 112 F, remove

the spa cover to cool the water. Overheating may occur if the filter cycle

is set too long. At 110 F, the spa should reset itself. If the high limit sensor

detects 118 F at the heater, the spa will shut down. When the heater

cools to 110 F, press any button to reset the spa. If the spa will not

reset, then shut off power to the spa and call your dealer or service

organization.

The spa is in standard mode and will continually heat to the set

temperature.

Standard

EcoN

The spa is in economy mode.

ECON

is flashed alternately with

COOL

and the current spa temperature and when the spa water is

more than 20 F cooler than the set temperature. The circulation

pump and heater will operate to warm the water to within 15 F of

the set temperature.

Economy

FLO

Flashing alternately with temperature. The filter may need cleaning.

The water level is too low. Be sure flow valves are open. Bleed

Circulation Pump if needed.

FLO

(NOT FLASHING) a pressure

switch has malfunctioned. Contact your dealer or service organization.

Flow

COOL

The spa water is more than 20 F cooler than the temperature last

set. No action is required. Spa is functioning properly. The circulation

pump and heater will operate to warm the water to within 15 F of the

set temperature.

Cool

The high-limit sensor or water temperature sensor is not working. Call

your dealer or service organization.

Sensor 1(Spa is deactivated)

S

n

3

The main sensor is not working. Call your dealer or service organization.

Sensor 3(Spa is deactivated)

Diagnostic Messages

ice

Ice

To p S i d e C o n t r o l I n s t r u c t i o n s