Priming Pump For Electric Packs

Turn off power at the breaker

It is important to make sure that all of the air is out of the equipment pack

before operating. To do this follow procedures below:

The Power pack system is located under the wood skirt. The equipment

can be serviced by simply opening the doors.

Set thermostat, located on top side control panel to desired temperature, and

continue heating until desired temperature has been reached. Depending

on equipment, this will normally take 8 to 10 hours.

Make sure the gate valves are open

Fill the spa with water going thru the filter
Turn the power on at the breaker
Start the pump on Hi-Speed and water will start circulating within

one to two minutes. (The pump is self-priming). If water does not circulate,

turn off the power and make sure all gate valves are open if so equipped.
Restart the pump. Within one to two minutes, it should be primed

G e n e r a l P r e - O p e r a t i o n I n s t r u c t i o n s

WARNING: Do not run spa with gate valves closed or run pump with

no water circulating in spa for long periods. This could damage

the spa equipment.

Air Blower

Ozonator

(Optional)

Equipment Pack

Gate Valves

Flow Thru

Heater

Circulation

Pump

(Optional)

Auxiliary Pump

(Optional)

2 Speed

High Performance

Pump