1 minute after the spa is energized. The second filter cycle will begin

12 hours after the start of the first filter cycle. Filter duration is programm-

able at the topside panel for 0, 1, 2, 3, 4 or 12 hours. To program, press

the SET pad, then the JETS pad. Press the SET pad again and F2 will be

displayed on the panel. (F2 is the default filter time and indicates a 2 hour

cycle). Continue pressing SET to cycle through the rest of the filter time

options, FO =O hour, F1 = 1 hour, F2 = 2 hours, F3 = 3 hours, F4 = 4 hours,

and FC = 12 hours. Press the JETS pad again to exit the programming mode.

During filtration, the low-speed pump will run and the blower (if installed)

operates for 30 seconds at the start of the first filter cycle to clean out

the air channel. If a circulation pump is installed, when the water is at set

temperature or below, it will run for 24 hours/day to constantly filter

the water. However, it turns off at 2 F above the set temperature and comes

back on for 1 hour every 3 hours until set temperature is reached again.

An ozone generator (if installed) also runs 24 hours/day.

OH

FL

S

n

Overheat Protection (Spa is deactivated)

If the high limit sensor detects 40 F at the heater, then the high speed

of pump 1 and pump 2 (if installed) automatically activates to provide

freeze protection. The equipment stays activated until the sensor detects

45 F at the heater. Freeze protection is activated regardless of the spa's

status. In colder climates, an optional additional freeze sensor may be

added to protect against freeze conditions. See your dealer for details.

DO NOT ENTER THE WATER. If the spa water has reached 112 F, remove

the spa cover to cool the water. Overheating may occur if the filter cycle

is set too long. At 110 F, the spa should reset itself. If the high limit sensor

detects 118 F at the heater, the spa will shut down. When the heater

cools to 110 F, press any button to reset the spa. If the spa will not

reset, then shut off power to the spa and call your dealer or service

organization.

Flow Switch Detection

The high-limit sensor or water temperature sensor is not working. Call

your dealer or service organization.

Sensor (Spa is deactivated)

Preset Filter Cycles (cont.)

Freeze Protection

Diagnostic Messages

The jets and blower (if installed) can also be activated from an

auxiliary panel. The operation is the same as described for the main

panel.

Auxiliary Panel (optional)

To p S i d e C o n t r o l I n s t r u c t i o n s

Flashing alternately with temperature. The filter may need cleaning.

The water level is too low. Be sure flow valves are open.

FLO

(NOT

FLASHING) a pressure switch has malfunctioned. Contact your dealer

or service organization.