beautypg.com

Rear panel – StorCase Technology DS550 User Manual

Page 14

background image

6

Introduction

StorCase Technology, Inc.

DS550 User's Guide - Rev. A04

Rear Panel

(Figure 4)

NOTE:

If a module slot is to be left empty, the filler plate (provided) must be installed.

Installation of the filler panel is necessary for proper cooling inside chassis.

•

SCSI I/O Connectors - The DS550 chassis is unwired and comes equipped with
rear panel cut-outs for up to six (6) I/Os.

•

Power Supply Module(s) - Dual auto-ranging power supply modules run in

Shared Mode which allows both to operate at reduced wattage and lower operating

temperature. In the event that one power supply should fail, the other will carry the

full load.

Blower Vent(s) - Two (2) adjustable dual-speed blowers (one in each power

supply module) provide ample cooling of chassis (79 CFM Total).

Module Handle(s) - Provide a sturdy grip for the installation and removal of the

power supply modules.

WARNING:

DO NOT USE MODULE HANDLES TO LIFT CHASSIS! These

handles are specifically designed for the installation and re-

moval of modules only!

Power Switch(es) - Rocker switch(es) control power to the power supply

module(s).

A/C Power In - Accepts U.S. and other available international standard power

cords.

Blower Speed Selector Switch(es) - Allow user to manually select between two

speeds (Low & High) for each blower. High speed (factory default) is recommended

for high performance (10K RPM and higher) drives.

NOTE:

In the event a blower fails, always set the speed of the remaining blower

to High.

Status LED(s) -

Green = Steady glow indicates normal power supply/blower operation.

OFF =

No glow indicates a fault in either the power supply or blower

(or both). Refer to the Indicator and Control Panel LEDs on the

front of the DS550 for further information.