StorCase Technology DE90i-S User Manual
Page 17
![background image](/manuals/742314/17/background.png)
12
Installation
Kingston Technology Company
DE90i-S, Rev. A00
Figure 8: Data Express Receiving Frame Mounting Holes
4.
To select the Data Express unit ID remotely through the computer system or
external expansion chassis, the appropriate cable from the system must be
connected to the ID select connector (J4) on the rear of the receiving frame as
shown in Figures 5 and 6.
IMPORTANT NOTE: In order to use remote ID selection from a computer or
expansion chassis, a three-wire connector must be connected
from the computer or expansion chassis to the ID0, ID1, and
ID2 pins of J4 of the receiving frame mother board as shown in
Figures 5 and 6. No ID jumpers are required for this type of
configuration. For on board ID selection, use the appropriate
jumpers on J4 as shown in Figure 7.
5.
With the drive carrier locked in place inside the receiving frame, install the Data
Express into the 5.25” drive opening in the computer or expansion chassis. Use
the appropriate guides to position the Data Express, and fasten it into place
with the four 6-32 x 1/4” screws provided. Figure 8 illustrates the location of the
mounting holes. Mounting holes are provided on each side and the bottom of
the receiving frame to accommodate a variety of mounting configurations. Use
the mounting holes which best suit the computer or expansion chassis
configuration. Note that bottom mounting holes require self tapping screws (not
provided).
6.
Adjust the front of the receiving frame so the carrier slides freely in and out on
the receiving frame guides. The position of adjoining peripheral units may
require adjustment.
0415
A
B
C
Receiving Frame
Side Mounting Holes
6-32 x 1/4" Screws
Provided (4 Plcs)
Receiving Frame
Mounting Holes.
Self Tapping Screws Not
Provided (4 Plcs)
Bottom Side of
Receiving Frame