beautypg.com

Installing the receiving frame – StorCase Technology DE90i-S User Manual

Page 16

background image

DE90i-S, Rev. A00

Kingston Technology Company

Installation

11

Installing the Receiving Frame

The drive should be installed into the carrier before installing the receiving frame into the
mounting bay of a computer or expansion chassis.

NOTE:

Use a #2 Phillips screwdriver during this procedure.

1.

Turn off power to the computer.

2.

Open the computer system according to the manufacturer’s instructions. If
necessary, temporarily remove any expansion boards that may make installation
difficult.

3.

Select the unit ID number on the rear of the receiving frame by placing jumpers on
the appropriate (J4) pins. Refer to Figure 7 and to Table 3 for additional information.

Table 3 - Receiving Frame Mother Board Connector J4 Pin Configuration

Pin 1

RESERVED

Pin 11

RESERVED

Pin 2

RESERVED

Pin 12

RESERVED

Pin 3

RESERVED

Pin 13

RESERVED

Pin 4

RESERVED

Pin 14

RESERVED

Pin 5

RESERVED

Pin 15

Ground

Pin 6

RESERVED

Pin 16

ID2

Pin 7

RESERVED

Pin 17

Ground

Pin 8

RESERVED

Pin 18

ID1

Pin 9

RESERVED

Pin 19

Ground

Pin 10

RESERVED

Pin 20

ID0

Figure 7: SCSI ID Select Pin Configuration on Receiving Frame Mother Board (J4)

Ground

0419

Receiving Frame
Mother Board
Connector J4

Installed

at Factory

SCSI ID = 0

SCSI ID = 1

SCSI ID = 2

SCSI ID = 3

SCSI ID = 4

SCSI ID = 5

SCSI ID = 6

SCSI ID = 7

ID1

ID2

ID0

ID NUMBER

Reserved

19

20

1

13

2

14

ID0

ID1

ID2