Use the following procedure to recalibrate the oven:
1. Loosen the two set screws that secure the temperature-control knob to the temperature-control shaft.
2. Remove the knob from the shaft, being careful not to rotate the knob or shaft.
3. Replace the knob on the shaft so that the indicator mark on the knob points directly at the temperature that was
measured at the center of the oven.
4. Re-check the oven calibration.
F
AHRENHEIT OR
C
ELSIUS
D
ISPLAY (Cycle/Cook & Hold Models Only)
Ovens with Cycle/Cook & Hold controls can be configured to display temperatures using the Fahrenheit or the Celsius
scales. To change the choice, change the position of the blue jumper “J3” on the rear of the control panel circuit board.