Xterior, Imensions, Entilation – Southbend S Series Restaurant Ranges User Manual
Page 7: Warning, Notice

OWNER’S MANUAL 1191904 REV 2 (5/14)
PAGE 7
OF 31
S
S
ERIES
R
ESTAURANT
R
ANGES
Model Number
Exterior Dimensions in Inches and (Millimeters)
Cook Top
Height
L
Door
Depth
M
Oven
Bottom
N
A
B
C
D
E
F
G
H
I
J
K
S24...
24.38”
(619)
34”
(864)
-
30”
(762)
31”
(787)
10”
(254)
2.75”
(70)
59.5”
(1511)
22.5”
(587)
31.0”
(787)
6”
(152)
37.0”
(914)
-
-
S36...
with convection oven
36.5”
(927)
41”
(1041)
7.8”
(185)
30”
(762)
31”
(787)
10”
(254)
2.75”
(70)
59.5”
(1511)
22.5”
(587)
31.0”
(787)
6”
(152)
37.0”
(914)
15.5”
(394)
13”
(318)
S36...
with standard oven
36.5”
(927)
34”
(864)
-
30”
(762)
31”
(787)
10”
(254)
2.75”
(70)
59.5”
(1511)
22.5”
(587)
31.0”
(787)
6”
(152)
37.0”
(914)
15.5”
(394)
13”
(318)
S48..
with covection oven
48.63”
(1235)
41”
(1041)
7.8”
(185)
30”
(762)
31”
(787)
10”
(254)
2.75”
(70)
59.5”
(1511)
22.5”
(587)
31.0”
(787)
6”
(152)
37.0”
(914)
15.5”
(394)
13”
(318)
S48...
with standard oven
48.63”
(1235)
34”
(864)
-
30”
(762)
31”
(787)
10”
(254)
2.75”
(70)
59.5”
(1511)
22.5”
(587)
31.0”
(787)
6”
(152)
37.0”
(914)
15.5”
(394)
13”
(318)
S60...
with convection oven
60.75”
(1543)
41”
(1041)
7.8”
(185)
30”
(762)
31”
(787)
10”
(254)
2.75”
(70)
59.5”
(1511)
22.5”
(587)
31.0”
(787)
6”
(152)
37.0”
(914)
15.5”
(394)
13”
(318)
S60...
with standard oven
60.75”
(1543)
34”
(864)
-
30”
(762)
31”
(787)
10”
(254)
2.75”
(70)
59.5”
(1511)
22.5”
(587)
31.0”
(787)
6”
(152)
37.0”
(914)
15.5”
(394)
13”
(318)
Dimensions O & P: Gas connection is on rear of range and is 3.25” (82mm) from left side and 30.25” (768mm) above the floor.
Dimensions Q & R: Electric connection is on rear of range and is 6” (152mm) from left side and 24” (610mm) above the floor. Ranges with dual ovens have two electric connections with the second connection
6” (152mm) from right side.
E
XTERIOR
D
IMENSIONS
WARNING
Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove flue products can
cause headaches, drowsiness, nausea, or could result in death.
All ranges must be installed in such a manner that the flow of combustion and ventilation air are not obstructed.
Provisions for adequate air supply must be provided. Do not obstruct the front of the range at the top by the control
panel, or the bottom just below the oven compartment, as combustion air enters through these areas.
V
ENTILATION
NOTICE
Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the
warranty.
Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer’s instructions.
Canopies are set over ranges, ovens, etc., for ventilation purposes. It is recommended that a canopy extend 6” past the
appliance and the bottom edge be located 78” above the floor. Filters should be installed at an angle of 45° or more from
the horizontal. This position prevents dripping grease and facilitates collecting the run-off grease in a drip pan, unusually
installed with a filter.
A strong exhaust fan tends to create a vacuum in the room and may interfere with burner performance or may extinguish
pilot flames. Fresh air openings approximately equal to the fan area will relieve such a vacuum.
The exhaust fan should be installed at least 2” above the vent opening at the top of the range.
If the range is connected directly to an outside flue, a CSA design-certified down draft diverter must be installed at the flue
outlet of the oven and connected to the flue.
In case of unsatisfactory performance on any appliance, check the appliance with the exhaust fan in the OFF position. Do
this only long enough to check equipment performance. Then turn hood back on and let it run to remove any exhaust that
may have accumulated during the test.
S
PECIFICATIONS