页 12, Setting, Error message – SkyRC T6200 Charger User Manual
Page 12
SETTING
T6200
T6200
21
20
ENTER
CAPACITY
CUT OFF
5000 mAh
120 Min
TEMP
CUT OFF
.
45 C/113 F
NEXT
HOME
SAFETY
PROTECTION
SAFETY
TIME OFF
Please touch and screen to make the functions ON or OFF. And touch “ ”
and “ ” to get the proper parameter.
NOTE: The TEMP CUT OFF function can not be OFF.
CAPACITY
CUT OFF
SAFETY
TIME OFF
▲
▲
3. CHARGER PARAMETER
ITEM
SELECTION
DESCRIPTION
This is the voltage level that T6200 will stop charging the
battery.
Intended ONLY for expert users and racers, completely at
their own risk, which allows LIPO and LIFE packs to be
charged in excess of recommended cell terminal voltages.
This is the voltage level that T6200 will stop discharging the
battery, and is shown as volts PER CELL in the pack (not total
pack voltage).
The battery is on the cyclic process of charge and discharge
can often become warm after charge or discharge period. The
program can insert a time delay to occur after each charge
and discharge process to allow the battery adequate time to
cool down before being subjected to the next process.
TERMINAL
VOLTAGE
CONTROL
(TVC)*
END VOLT
DISCHARGE
REST TIME
END VOLT
CHARGE
.
REST
TIME
4.20V
60 Min
ENTER
HOME
CHARGER
PARAMETER
END VOLT
DISCHARGE
.
3.20V
Please touch “ ” and “ ” to get the proper parameter.
▲
▲
1-120 min
LiPo
Lilon
LiFe
4.18-4.3V/Cell
4.08-4.2V/Cell
3.58-3.7V/Cell
LiPo
Lilon
LiFe
NiMH
NiCd
Pb
3.0-3.3V/Cell
2.9-3.2V/Cell
2.6-2.9V/Cell
0.1-1.1V/Cell
0.1-1.1V/Cell
1.8V/Cell
ENTER
NEXT
SETTING
SAFETY
PROTECTION
ENTER
NEXT
SETTING
CHARGER
PARAMETER
"
INT. TEMP TOO HIGH"
"EXT. TEMP TOO HIGH"
"DC IN TOO LOW"
"DC IN TOO HIGH"
"OVER TIME LIMIT"
"OVER CAPACITY LIMIT"
"REVERSE POLARITY"
"CONNECTION BREAK"
"CELL NUMBER ERROR"
"BALANCE CONNECTER ERROR"
"NO BATTERY"
"CONNECTION ERROR"
"BATTERY WAS FULL"
It incorporates a variety of functions for the systems to verify processes and the state of the
electronics. In case of an error the screen will display the cause of error and emit an audible
sound.
Incorrect polarity connected.
The battery is interrupted.
The Battery connection is wrong.
The cell number is wrong.
The internal temperature of the unit goes too high.
Input voltage less than 11V.
Input voltage higher than 18V.
The battery voltage is higher than the maximum
voltage which the user sets when charging in
balance mode.
The external temperature of the unit goes too high.
The battery capacity is more than the maximum
capacity which the user sets.
The charging time is longer than the maximum
charging time which the user sets.
The balance connect is wrong.
There is no battery connecting to the charger.
ERROR
MESSAGE
EXPLANATION
ERROR MESSAGE
ERROR MESSAGE
WARNING! By setting the TVC to any POSITIVE SETTING above default value, you ACCEPT ALL RESPONSIBILITY for
DAMAGE to your battery, FIRE, INJURY, and any other loss which may result. If you do not agree to accept all risk, DO
NOT OPERATE YOUR CHARGER UNLESS ALL TVC POSITIONS ARE SET TO DEFAULT VALUE!