LITHIUM BATTERY METER

PROGRAM SELECT
Li BATT METER

Move the joystick right to enter the Lithium
Battery Meter program.

4.19 4.15 4.18V
0.00 0.00 0.00V

The screen indicate each cell's voltage.

MAIN 12.52V
H4.190V L4.160V

The screen indicate the total voltage, the highest
voltage, the lowest voltage.

The user can check battery's total voltage, the highest voltage, the
lowest voltage and each cell's voltage.
Please connect the battery to the charger main battery lead to battery
socket and balance wires to balance socket.

This diagram shows the correct way to connect your battery to
check the voltage.

RIGHT

SYSTEM SET UP

It will be operated with the default value of the essential user settings
when it is connected to a DC 11~18V battery for the first time. The
screen displays the following information in sequence and the user can
change the value of parameter on each screen.
When you are willing to alter the parameter value, move the joystick
right to make it blink then change the value by moving the joystick
up/down. The value will be stored by re-moving the joystick right.

PROGRAM SELECT
SYSTEM SET

Rest Time
CHG>DCHG 10Min

SAFETY TIME
ON 120Min

User set up starting screen.

The battery is on the cyclic process of charge
and discharge can often become warm after
charge or discharge period. The program can
insert a time delay to occur after each charge
and discharge process to allow the battery
adequate time to cool down before being
subjected to the next process. The value
ranges from 1 to 60 minutes.

When you start a charge process, the integral
safety timer automatically starts running at the
same time. This is programmed to prevent
overcharge the battery if it proves to be faulty,
or if the termination circuit cannot detect the
battery full. The value for the safety timer
should be generous enough to allow a full
charge of the battery.

Safe timer Calculation
When charging NiMH or NiCad batteries,
divide the capacity by current, then divide the