beautypg.com

页 24, Warning and error message – SkyRC Quattro B6AC User Manual

Page 24

background image

WARNING AND ERROR MESSAGE

It incorporates a variety of functions for the systems to verify processes and the state of the
electronics. In case of an error the screen will display the cause of error and emit an
audible sound.

Incorrect polarity connected.

The battery is interrupted.

CONNECT error
Check Main Port

The Battery connection is wrong.

The cell number is wrong.

CELL number
Incorrect

Voltage of one cell in the battery pack is too high.

CELL error
High Voltage

Voltage of one cell in the battery pack is too low.

CELL error
Low Voltage

The internal temperature of the unit goes too high.

Int.temp.too hi

DC in too low

Input voltage less than 11V.

Input voltage higher than 18V.

DC in too high

BATTERY WAS FULL

The battery voltage is higher than the maximum voltage
which the user sets when charging in balance mode.

CELL error
Voltage-Invalid

Voltage of one cell in the battery pack is invalid.

The external temperature of the unit goes too high.

Ext.temp.too hi

Over charge
Capacity Limit

The battery capacity is more than the maximum capacity
which the user sets.

Over TIME LIMIT

The charging time is longer than the maximum charging
time which the user sets.

BALANCE CONNECT
ERROR

The balance connect is wrong.