页 15 – SkyRC Quattro B6AC User Manual
Page 15
LITHIUM BATTERY(LIPO/LILO/LIFE)PROGRAM
'STORAGE' CONTROL OF LITHIUM BATTERY
DISCHARGING LITHIUM BATTERY
At this screen, you can set up the current and voltage of the
battery pack. Charging and discharging will make the batteries
come to the voltage level of storage state.
This is for charging or discharging Lithium battery not to be used for the time being. The
program will determine to charge or discharge the battery to the certain voltage depending
on the voltage of the battery at its initial stage. They are different from the type of the
battery, 3.75V for LiIo, 3.85V for LiPo and 3.3V for LiFe per cell. If the voltage of battery at
its initial stage is over the voltage level to storage, the program will start to discharge.
This screen shows the real-time status charging. Press Batt
Type/Stop key once to stop the charge process.
Number
of
cells
DEC
- +
Batt type
Stop
Elapsed
time
INC
Charge
or discharge
current
Supplied
capacity
DEC
Start
Enter
-
INC
+
Current
voltage
battery
'> 3 seconds '
Start
Enter
This displays the number of cells you set up and the processor
detects. R shows the number of cells detected by the charger and
S is the number of cells set by you at the previous screen. If both
numbers are identical you can start charging by press Start/Enter
button. If not, press Batt Type/Stop button to go back to previous
screen to carefully check the number of cells of the battery pack
before going ahead.
The value of discharge current on the left can not exceed 1C, and
the value on the right can not be under the voltage recommended
by the manufacturer to avoid deep discharging. Press Start/Enter
for more than 3 seconds to start discharging.
This shows the real-time status of discharging, you can press
Batt Type/Stop key to stop discharging.
Number
of
cells
DEC
-
Batt type
Stop
elapsed
time
INC
+
Battery
voltage
DEC
Start
Enter
-
INC
+
Discharged
capacity
discharge
current
'> 3 seconds '
Start
Enter
This displays the number of cells you set up and the processor
detects. R shows the number of cells detected by the charger and
S is the number of cells set by you at the previous screen. If both
numbers are identical you can start charging by press Start/Enter
button. If not, press Batt Type/Stop button to go back to previous
screen to carefully check the number of cells of the battery pack
before going ahead.