页 16, Pb( lead-sulphuric acid) battery program, Discharging of pb battery – SkyRC Quattro B6AC User Manual
Page 16: Charging of pb battery

PB( LEAD-SULPHURIC ACID) BATTERY PROGRAM
This is programmed for charging Pb(lead-sulphuric acid) battery with nominal voltage from 
2 to 20V. Pb batteries are totally different from NiCd or NiMH batteries. They can only 
deliver relatievely lower current compare to their capacity, and similar restrictions definitely 
apply to charge. So the optimal charge current will be 1/10 of the capacity. Pb batteries 
must not be charged rapidly. Always follow the instruction is supplied by the manufacturer 
of battery.
When you are willing to alter the parameter value in the program, press Start/Enter key to 
make it blink then change the value with INC or DEC key. The value will be stored by 
pressing Start/Enter key once.
DISCHARGING OF PB BATTERY
Battery
type
DEC
-
Batt type
 Stop
Elapsed
time
INC
+
Charge 
current
Battery
voltage
DEC
Start
Enter
-
INC
+
Charged
capacity
'> 3 seconds '
DEC
-
Batt type
 Stop
INC
+
DEC
Start
Enter
-
INC
+
Battery
type
Elapsed
time
Discharge 
current
Battery
voltage
Discharged
capacity
'> 3 seconds '
Set up the charge current on the left and the nominal voltage of 
the battery on the right. The charge current ranges from 0.1 to 
6.0A and the voltage should be matched with the battery being 
charged.
Start the charge process by pressing Start/Enter key for more 
than 3 seconds.
The screen displays the state of charging process. To stop 
charging forcibly, press Batt type/Stop key once.
The audible sound indicates you at the end of process.
Set discharge current on the left and final voltage on the right. 
The discharge current ranges from 0.1 to 2.0A.
To start the process, press Start/Enter key for more than 3 
seconds.
The screen displays the current state of discharge. You can alter 
the discharge current by pressing Start/Enter key during the 
process. Once you change the current value, store it by pressing 
Start/Enter button again.
To stop discharging press Batt Type/Stop key once. The audible 
sound indicates you at the end of process.
CHARGING OF PB BATTERY