页 21, Program set up, For example – SkyRC Quattro B6AC User Manual
Page 21: User set up starting screen
PROGRAM SET UP
It will be operated with the default value of the essential user settings when it is connected
to a DC 11~18V batttery for the first time.The screen displays the following information in
sequence and the user can change the value of parameter on each screen.
When you are willing to alter the parameter value in the program, press Start/Enter key to
make it blink then change the value with INC or DEC key. The value will be stored by
pressing Start/Enter key once.
PROGRAM SELECT
SYSTEM SET
User set up starting screen.
Rest Time
CHG
>DCHG 10Min
The battery is on the cyclic process of charge and
discharge can often become warm after charge or
discharge period. The program can insert a time delay to
occur after each charge and discharge process to allow the
battery adequate time to cool down before being subjected
to the next process. The value ranges from 1 to 60 minutes.
SAFETY TIME
ON 120Min
When you start a charge process, the integral safety timer
automatically starts running at the same time. This is
programmed to prevent overcharge the battery if it proves
to be faulty, or if the termination circuit cannot detect the
battery full. The value for the safety timer should be
generous enough to allow a full charge of the battery.
Safe timer Calculation
When charging NiCd or NiMH batteries, divide the capacity
by current, then divide the result by 11.9, set this number as
the value for safety timer setting. If the charger stopped at
this threshold, about 140% of the capacity will have been
fed into the battery.
Capacity
Current
Safety Time
2000mAh
2.0A
(2000/2.0=1000)/11.9=84 minutes
3300mAh
3.0A
(3300/3.0=1100)/11.9=92 minutes
1000mAh
1.2A
(1000/1.2=833)/11.9=70 minutes
For example:
INC
DEC
INC
DEC
INC
DEC
INC
DEC
INC
Capacity Cut-Off
ON 5000mAH
This program sets the maximum charge capacity that will
be supplied to the battery during charge. If the deltapack
voltage is not detected nor the safety timer expired by any
reason, this feature will automatically stop the process at
the selected capacity value.
DEC
INC
DEC
INC
DEC
INC
DEC
INC
Key Beep ON
Buzzer ON
The beep sounds at every time pressing the buttons to
confirm your action. The beep or melody sounded at
various times during operation to alert different mode
changes.
These audible sounds can be on or off.
DEC
INC
D E C
I NC