页 21, Program set up, For example – SkyRC Quattro B6AC User Manual
Page 21: User set up starting screen

PROGRAM SET UP
It will be operated with the default value of the essential user settings when it is connected 
to a DC 11~18V batttery for the first time.The screen displays the following information in 
sequence and the user can change the value of parameter on each screen.
When you are willing to alter the parameter value in the program, press Start/Enter key to 
make it blink then change the value with INC or DEC key. The value will be stored by 
pressing Start/Enter key once.
PROGRAM SELECT
 SYSTEM SET
User set up starting screen.
Rest Time
CHG
>DCHG 10Min
The battery is on the cyclic process of charge and 
discharge can often become warm after charge or 
discharge period. The program can insert a time delay to 
occur after each charge and discharge process to allow the 
battery adequate time to cool down before being subjected 
to the next process. The value ranges from 1 to 60 minutes.
SAFETY TIME
ON 120Min
When you start a charge process, the integral safety timer 
automatically starts running at the same time. This is 
programmed to prevent overcharge the battery if it proves 
to be faulty, or if the termination circuit cannot detect the 
battery full. The value for the safety timer should be 
generous enough to allow a full charge of the battery.
Safe timer Calculation
When charging NiCd or NiMH batteries, divide the capacity 
by current, then divide the result by 11.9, set this number as 
the value for safety timer setting. If the charger stopped at 
this threshold, about 140% of the capacity will have been 
fed into the battery.
Capacity
Current
Safety Time
2000mAh
2.0A
(2000/2.0=1000)/11.9=84 minutes
3300mAh
3.0A
(3300/3.0=1100)/11.9=92 minutes
1000mAh
1.2A
(1000/1.2=833)/11.9=70 minutes
For example:
INC
DEC
INC
DEC
INC
DEC
INC
DEC
INC
Capacity Cut-Off
ON 5000mAH
This program sets the maximum charge capacity that will 
be supplied to the battery during charge. If the deltapack 
voltage is not detected nor the safety timer expired by any 
reason, this feature will automatically stop the process at 
the selected capacity value.
DEC
INC
DEC
INC
DEC
INC
DEC
INC
Key Beep ON
Buzzer ON
The beep sounds at every time pressing the buttons to 
confirm your action. The beep or melody sounded at 
various times during operation to alert different mode 
changes.
These audible sounds can be on or off.
DEC
INC
D E C
I NC
