beautypg.com

0 chronograph mode, 1 chronograph mode, 0 countdown timer mode – Q&Q QUARTZ L105J User Manual

Page 2: 1 countdown timer mode, 2 countdown timer mode, 3 countdown timer mode, 4 countdown timer mode, 0 dual time mode, 1 dual time mode, 0 specifications

background image

counting

time

starting value (hour, mintue)

Timer 4 Display

Timer 3 Display

Timer 1 Display

Timer 2 Display

Countdown Timer Mode

[L/R]

[L/R]

[L/R]

[L/R]

Timer 1*

Timer 3*

Multi-Timer Counting Sequence

Timer 2*

Timer 4*

D If Timer 1, 2, 3 or 4 which set 0:00 as the

starting value, that timer will be excluded
from the counting sequence.

7.0 Chronograph Mode -

Chronograph Mode

3. Lap times

time

[S/S]

[S/S]

[S/S]

[S/S]

[L/R]

[L/R]

[L/R]

[S/S]

[S/S]

[S/S]

0

10

20

30

30

0

20

10

10

10

0

10

0

10

lap 1

lap 2

lap 3

2. Accumulative elapsed time

1. Elapsed time

Elapsed time, Accumulative

Elapsed time and Lap time

Chronograph Display

'All Zero'

accumulative
running time
(1/100 second)
accumulate
running time
(second)

accumulative
running time
(minute)

accumulative
running time
(hour)

current lap
running time

Chronograph Mode
+ This Watch includes a stopwatch function which measures:

+ Elapsed time, accumulative elapsed time (multi-phase elapsed time)

and Lap time (get a elapsed time without stopping the counting).

+ The measuring capacity of the chronograph:

+ Measuring unit: 1/100 second,
+ Measuring range: 9 hours, 59 minutes and 59.99 second,
+ Lap Memory: a maximum of 50 laps.

Chronograph Display
+ When the Chronograph Display is selected, the Watch will show the

following items on the display:
+ During the chronograph is counting: The current lap time and the

accumulative elapsed time is exhibited on the 1st and 2nd row
respectively. NOTE: The current lap time will be the same as the
accumulative elapsed time for lap 1.

+ During the chronograph is stopped: The current lap time and lap

number are exhibited on the 1st row, and the accumulative elapsed
time is exhibited on the 2nd row.

+ During the Lap Display is displaying: The current lap number and

the lap time is exhibited on the 1st and 2nd row respectively.

7.1 Chronograph Mode -

Using the Chronograph

Counting Display

[L/R]

5 seconds

Lap Time Display

Stop Counting Display

hold [L/R]

elapsed

time

(counting)

elapsed

time

(stop

counting)

[S/S]

[S/S]

All Zero Display

lap time

lap
number

How to Measure Elapse Time
+ During the 'All Zero' Display, press the [S/S] button once will start

the counting, and press the [S/S] button again will stop the
counting.

+ The elapsed time between the above 2 key-stokes will be

exhibited on the 1st row of the display. Repeat the above key
operations to get the accumulative elapsed time.

How to Get a Lap Time
+ When the chronograph is counting, press the [L/R] button to get

and view the Lap Display for 5 seconds. In the Lap Display, the
current lap number and lap time will appear on the 1st and 2nd
row of the display respectively.

+ After the 5 seconds, the Watch will return to counting display

automatically. Then the new lap time and the accumulative
elapsed time will be exhibited on the 1st and 2nd row of the
display respectively. Repeat the above key operations to get
another lap time.

How to Recall/Reset the Lap Time
+ During the chronograph is stopped:

+ Press the [L/R] button one by one to review the recorded lap

times, or

+ Hold down the [L/R] button for about 2 seconds to clear the lap

time, and reset the display to 'All Zero' display.

8.0 Countdown Timer Mode -

Countdown Timer Display

Countdown Timer Mode
+ This Watch includes 4 countdown timers. They are Timer 1, 2, 3 and 4.

Using one timer (Single Timer) which can run normal timer function. But
combines two or more timers (Multi-Timer) can extend the timer function to
measure multi-phase elapse time.

+ The measurement unit of these timers is 1 second, and the starting value of

these timers can be set up to a maximum of 23 hours and 59 minutes.

+ When a timer which set 0:00 as the starting value, that timer will be excluded

from the counting sequence.

+ When the timer is started, the Watch will count repeatingly unless it is

stopped by pressing the [S/S] button. During the counting, the Watch will
beep once when a timer counts to the last 1 and 0 second

Single Timer and Multi-Timer
+ When using Single Timer (one timer), it must excludes other timers from the

counting sequence by setting their starting value to 0:00.

+ When using Multi-Timer, it is counting on a sequence which starts the

counting from Timer 1 to another timers following the adjacent diagram.

How to Select Different Timer Display
+ To select different countdown timer display during the timer is stopped, press

the [L/R] button one by one following the adjacent diagram.

8.1 Countdown Timer Mode -

Setting the Countdown Timer

Countdown Timer Display

minute

hour

Setting Sequence

[S/S]

hold [M]

[M]

Increase
the number

increase
the number
at a higher
speed

[L/R]

hold [L/R]

How to Set the Countdown Timer
+ The following paragraphs will illustrate the procedure for

setting the timer 1. Even so, setting the other timers will work
on the similar procedure.

+ To select the setting display, hold down the [M] button for 2

seconds in the Timer 1 Display, and then the 'Minute' digits
start flashing on the display.

+ In setting display, press the [S/S] button to move the flashing

following the adjacent diagram to select among different
settings.

+ When one of the settings (minute, hour) is flashing, press the

[L/R] button to change the number (hold down the button to
change the number at a higher speed).

+ When the setting is completed, press the [M] button once to

exit the setting display. The Watch will also exit the setting
display if NO key-stoke has been activated for 1 minute.

8.2 Countdown Timer Mode -

Loading and Resetting the Timer

Countdown Timer Display

Stop Counting

hold

[L/R]

hold

[L/R]

load the
timer(s)
into the
counting
sequence

reset all
starting
values
to zero

[L/R]

Confirm
the loading
or
resetting

Abort
the loading
or
resetting

[M]

[L/R]

How to Load the Timers

+ If the starting value has been set for the timer(s), they must be

loaded into the counting sequence before it is ready for

counting.

+ To load the timer(s) into counting sequence, hold down the [L/R]

button in Timer Display (when the timer is stopped) until the 'Ld

ALL' indicator appeared following the adjacent diagram.

+ When the 'Ld ALL' indicator is appeared, press the [M] or [L/R]

to confirm or abort the loading.

+ If the Timer Display is returned after the loading, the timer(s) is

ready to count.

How to Reset the Timers

+ During the 'Ld ALL' indicator is appeared, hold down the [L/R]

button until the 'cLR ALL' indicator appeared following the

adjacent diagram.

+ When the 'cLR ALL' indicator is appeared, press the [M] or

[L/R] to confirm or abort the resetting.

+ If the Timer has been reset, all starting values will be reset to

0:00.

8.3 Countdown Timer Mode -

Using the Single Timer

How to Use the Single Timer

+ When using one timer only (Single Timer), excludes other

timers by setting their starting values to 0:00.

+ Once the starting value has been set for the last timer, it must

be loaded into the counting sequence before it is ready for

counting. Check previous chapter 8.2 for more detail on how

to load the starting value into the counting sequence.

+ Press the [S/S] button to start the counting. The counting will

be restarted automatically when it reaches zero unless the

counting is stopped by pressing the [S/S] button.

How to Re-load the Timer

+ To re-load the timer to its original starting value during the

timer is stopped, perform the loading process following the

previous chapter 8.2.

Timer Alarm Sound

+ During the counting, the Watch will beep once when a timer

counts to the last 1 and 0 second.

Timer 1 Display

Counting Display

Counting

Display

Counting Display

Zero Display

[S/S]

[S/S]

[S/S]

[M]

hold

[L/R]

Stop Counting Display

stop

counting

counting

beep, beep

8.4 Countdown Timer Mode -

Using the Multi-Tmer

9.0 Dual Time Mode -

Dual Time Mode

9.1 Dual Time Mode -

Setting the Dual Time

10.0 Specifications

Countdown Timer

+ Timer: 4 timers

+ Resolution: 1 second

+ Measuring Range: 23 hours 59 minutes

+ Timer Sounds: the Watch will beep once

when a timer counts to the last 1 and 0

second.

Pacer Mode

+ Setting Range: 40 bpm to 180 bpm

+ Setting step: 5 bpm
Dual Time Mode

+ Time System: AM, PM, Hour, minute, second

Current Time Mode

+ Time System: AM, PM, Hour, minute,

second

+ Time Format: 12-hour or 24-hour format

+ Calendar: Month, date and day of week

display (Auto-Calendar function for leap year

and day of week)

Alarm Mode

+ Daily alarm and hourly chime

+ Alarm sound: 20 seconds
Chronograph Mode

+ Resolution: 1/100 second

+ Measuring Range: 9 hours 59 minutes 59.99

seconds

+ Lap memory: 50 lap memories

Dual Time Mode

minute

hour

Setting Sequence

[S/S]

hold [M]

[M]

Increase
the number

increase
the number
at a higher
speed

[L/R]

hold [L/R]

To Set the Dual Time

+ To select the setting display, hold down the [M] button for 2

seconds in the Dual Time Mode, and then the 'Minute' digits

start flashing.

+ In the setting display, press the [S/S] button to select the

flashing (setting item) as shown in the diagram.

+ When one of the settings (minute, hour) is flashing, press the

[L/R] button to change the number; hold down the button to

change the number at a higher speed.

+ When the setting is completed, press the [M] button once to

exit the setting display. The Watch will also exit the setting
display if NO key-stoke has been activated for 1 minute.

Dual Time Mode

dual time
(second)

dual time
(minute)

dual time
(hour)

Dual Time Mode

+ This Watch includes a dual time which show the current

time of the second time zone.

+ The second digits are same as the one of current time.
Dual Time Display

+ When the Dual Time Display is selected, the dual time

(hour, minute, second) is exhibited on the 2nd row of the

display.

hold [L/R]

hold

[L/R]

Reset the

Starting Values

Load the

Starting Values

Confirm
the loading
or
resetting

Abort
the loading
or
resetting

[M]

[L/R]

Timer 1*

Timer 3*

Multi-Timer Counting Sequence

The counting

is stopped

Timer 2*

Timer 4*

D If timer 1, 2, 3 or 4 which set 0:00 as the

starting value, that timer will be

excluded from the counting sequence.

[S/S]

[S/S]

beep, beep

beep,

beep

beep,

beep

beep, beep

How to Use the Multi-Timer
+ To use the Multi-Timer function which combines two or more

timers to measure multi-phases elapse time, it must set the

starting value for each timer.

+ Once the starting value has been set for the timer(s), they

must be loaded into the counting sequence before it is ready

for counting. Check the previous chapter 8.2 for more detail on

how to load the timer into the counting sequence.

+ Pressing the [S/S] button will start the counting sequence. The

Multi-Timers will starts the counting from Timer 1 to another

timers following the adjacent diagram. Pressing the [S/S]

button once again will stop the counting.

+ The Watch will count repeatingly unless it is stopped by

pressing the [S/S] button.

Timer Alarm Sound
+ During the counting, the Watch will beep once when a timer

counts to the last 1 and 0 second.

How to Re-load/Reset the Starting Values
+ To re-load or reset the Starting Values during the timer is

paused, perform the loading or resetting process which

mentioned in the adjacent diagram to re-load or reset the

starting vales.

Setting Sequence