Lodar 4 Function AC relay Receiver, Master and IP Series Transmitter User Manual
Page 4
Connection Detail - Switch V
oltage and Supply V
oltage are different,
Say mains supply and switching 48 V
olts
AC from a transformer
*If a switch is not used, its input must still be wired, otherwise if its corresponding
T
ransmitter Function is operated in error the Receiver will immediately switch of
f.
NOTE
Operating when the switched
V
oltage is at low as 48 V
olts,
the LED’
s will be very dim!
F1
Safety
F1
Switch
F2
Safety
F2
Switch
F3
Safety
F3
Switch
F4
Safety
F4
Switch
M
Safety
M
Switch
Power Supply
90 - 264 V
AC
for control circuits
ST -
LK1
LK2
RS232
ANT
Radio Module
Internal Aerial
glue
W
ire is not supplied with Lodar 96 and 97 Series systems, local wiring regulations apply
48 V
olts
AC
from
transformer
Secondary
Common Live
Output 1
Output 2
Output 3
Master Output
Primary
power
supply
Earth
Live (Hot)
Neutral
Secondary
Neutral
48 V
olts
AC
from
transformer
required for
safety circuit
Common Live Loop
Important
ALL
inputs must
be wired
*
see note below
- 2 Function AC relay Receiver, Master and IP Series Transmitter 2 Function AC relay Receiver and IP Series Transmitter 4 Function AC relay Receiver, Master and Standard Transmitter 2 Function AC relay Receiver, Master and Standard Transmitter 2 Function AC relay Receiver and Standard Transmitter 2 Function AC relay Receiver and Mini Transmitter