Wiring Instructions for 11 Series 2 Function Receivers

2

or Disconnect Battery

IDENTIFY POWER

CONNECTION POINT

AND ISOLATE SUPPLY

Fuse

Remove fuse

Vehicle batteries contain gasses
which are flammable and explosive.
Wear eye protection and do not lean
over battery while disconnecting. Do
not wear metal jewellery.

!

WARNING

1

!

BEFORE YOU START

A1102 RX
& A1102E RX
have
7 core cable

A1100 RX
has 4 core
cable

3

Secure using 5mm (3/16") bolts (not supplied)

through the 2 mounting feet

CAUTION

MOUNT RECEIVER

STOP

POSITIVE

NEGATIVE

!

TAKE TIME TO LOCATE THE BEST POSITION

If necessary, power the Receiver and move it around
the vehicle until the required performance is achieved.
Operate the Transmitter and observe the Receiver
internal LED’s.

Mount as HIGH as possible
AVOID surfaces with HEAVY VIBRATION
AVOID
DIRECT SPRAY from wheels
In a HOT CLIMATE fit in a SHADED position
Cable gland should face DOWN or BACK

Receiver 90 and 91 Series (Black lid)
Waterproof to IP67 complete with 1.5 metres (5ft) cable

1.

The Receiver is designed to carry a maximum of 8 Amps, with an individual output maximum

of 5 Amps. If you need to switch higher currents, then the you should consider the 92 or the

93 series which can switch up to 15 Amps.

2.

Master Output. This can be configured to Continuous or Parallel operation, see overleaf for

details. (This feature is not available on 90 1 00 and 91 1 00 models)

3.

Receiver outputs, when connected in parallel with an external switching device (wired

remote), will instantly switch off if the wired remote is operated. This is a feature of the

safety circuits.

4.

Lodar Receivers

have an isolation switch for safety and to allow for registering a

MUST

replacement Transmitter.

5.

Safety Feature. Both the Transmitter and the Receiver will switch off after 30 minutes of

inactivity. Other Timeouts are available, ask your dealer.

CONNECT

WIRES

4

Transmitter

Function

Convention

F1

F2

5

or re-connect Battery

ACTIVATE THE

RECEIVER SUPPLY

Fuse

Replace fuse

Press the Transmitter

button

RESET

to activate the system, and carefully
test each function for correct operation.

7

TEST

6

CONNECT TRANSMITTER BATTERY

Batteries generally have to be

disconnected when shipping.

12/24 Volts DC Nominal
Positive Supply

RED

BLACK

GREEN

YELLOW

BROWN

WHITE

Master

Wire Colour

Not Present

Not Present

Not Present

Not Used

Not Used

Make notes about the

connections made

in the boxes below

What is the MASTER Output for ?

It is used to operate the pump of an electro-hydraulic
power pack or maybe a clutch pump. It can also be
used for powering a dump valve, master valve etc.
It can be configured to work continuously, that is ON
when SET is pressed and OFF when STOP is
pressed; or in parallel with any output, that is, it is
active only a function is operated. If it is needed with
certain functions only, this can easily be configured.

Wire used for

Zero Volts (Ground)

Output Function 1

Output Function 2

Secondary Master

BLUE

E-Stop Loop

E-Stop Loop

BROWN

Not Present

Option

11 100

11 102

11 102E

lodar.com

T

I

Option

Option

Table of contents