IDENTIFY POWER
CONNECTION POINT
AND
ISOLATE SUPPLY
9604 RX STX.01E
1.
The Receiver is designed to carry a maximum of 10 Amps per output.
2.
Master Output. This can be configured to Continuous or Parallel operation, see overleaf for
details.
3.
If Receiver relay pairs MUST have a common live supply connected for the Receiver to work!
Else the Receiver will instantly switch off when a Transmitter function is operated.
4.
Lodar Receivers
have an isolation switch for safety and to allow for registering a
MUST
replacement Transmitter.
5.
Safety Feature. Both the Transmitter and the Receiver will “time out” after 30 minutes of
inactivity. This can be altered, ask your dealer.
1
!
BEFORE YOU START
Wiring Instructions for 96 Series & 97 Series 2 & 4 AC Function Receivers
3
Secure using 5mm (3/16") bolts (not supplied)
through the 4 mounting feet
TAKE TIME TO LOCATE THE BEST POSITION
If necessary, power the Receiver and move it around
the vehicle until the required performance is achieved.
Operate the Transmitter and observe the Receiver
internal LED’s.
Mount as HIGH as possible
AVOID surfaces with HEAVY VIBRATION
In a HOT CLIMATE fit in a SHADED position
Cable gland should face DOWN or BACK
Receiver 96 04 RX and 97 04 RX shown,
Waterproof to IP67
CAUTION
MOUNT RECEIVER
!
FM Series - Effective working range up to a distance of 60 metres (200 feet).
Narrow Band FM Series - Effective working range up to a distance of 300 metres (1000 feet)
FCC ID: M2H LODAR 8522
This devise complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions, (1) This devise may not cause
harmful interference and, (2) this devise must
accept any interference received, including
interference that may cause undesired
operation.
Serial No.
Model No.
92104TX
200000
e
11 023087
www.lodar.com
!
www.lodar.com
9000
!
F1
F2
F3
F4
Front
Battery
Compartment
Release Catch
Button switches off
STOP
the Receiver and the keypad
function buttons
L.E.D.
Blinks when Transmitter
and Receiver are active.
ON when a Transmitter
Button is pressed.
Pulses while transmitting
when battery is low.
New feature May 2010
The Transmitter automatically
transmits a
signal after
STOP
30 minutes; this de-activates
the Receiver and the Transmitter
keypad.
!
SAFETY FEATURE
Yellow
Function Buttons
RESET Button
activates the
Receiver and
the keypad
function buttons
Lo-Cover not shown
Your product is marked with this symbol. It means that used electrical and electronic products
should not be mixed with general household waste. There is a separate collection system for
these products.
In the EEC - Please contact your National Distributor (see www.lodar.com for this information) who
will inform you about the take-back of the product. You might be charged for the costs arising from
the take-back and recycling. Small products might be taken back by your local collection facilities.
Outside the EEC - If you wish to discard this product please contact your local authorities and
ask for the correct method of disposal
Press the Transmitter
button to activate
RESET
the system, and carefully
test each function for
correct operation.
TO TEST
- 2 Function AC relay Receiver, Master and IP Series Transmitter 2 Function AC relay Receiver and IP Series Transmitter 4 Function AC relay Receiver, Master and Standard Transmitter 2 Function AC relay Receiver, Master and Standard Transmitter 2 Function AC relay Receiver and Standard Transmitter 2 Function AC relay Receiver and Mini Transmitter