Timing Retard Activation (Cont...)

LNC-2001 Receiving +12V Retard Activation Input from the

Dedenbear Lightning Delay Box

Use this wiring configuration to allow a Dedenbear Lightning (L1 or L2) or Command Center 3 (CC-3)

Delay Box to control the +12V retard activation for the LNC-2001.

• The +12V retard activation (orange) wire can be connected to either the Throttle Stop A or Throttle

Stop B output on the Dedenbear Delay Box.

• The output from the delay box should be configured for two timers with the first timer being set to

zero and the second timer being set to the point in time where timing should no longer be pulled.

• It is important to note that the location of the Throttle Stop A and Throttle Stop B terminals on the

terminal barrier strip is different depending on the Dedenbear Delay Box model that you are using.

Refer to your delay box installation instructions for the location of these terminals.

LNC-2001

Red = MAP +5V
Black = MAP/Linear Ground
Purple = MAP/Linear Signal

F

= Linear Mode

.2 Volt = 0*
4.8 Volt = 15*

Max Retard

STOPA

STOPB

RSET

TBRK

MODE

A B TB

P/F

Throttle Stop B

Throttle Stop A

+12V LNC-2001 Retard

Activation Input (Orange)

The “Dedenbear Lightning Delay Box” name and