LNC-2001

Red = MAP +5V
Black = MAP/Linear Ground
Purple = MAP/Linear Signal

F

= Linear Mode

.2 Volt = 0*
4.8 Volt = 15*

Max Retard

Momentary Switch MUST be capable of supplying current

draw of Linelock Solenoid. If switch is rated at a lower amperage

then the solenoid, a Relay MUST be used. See Diagram for

Manual Transmission installation for Relay wiring details.

Optional LED, On when

Arming Switch is ON.

Automatic Transmission with Linelock

Retard Activation Connect to Nitrous
WOT switch signal or to +12V relay
output from Nitrous controller.

Analog Output
0-3 volt, .2 volt per 1* of Retard
Connect to analog input of Data
Recorder.

Use this configuration to activate Linelock and the 2-step function using a momentary push-button switch.

Once the toggle switch is flipped ON and the momentary switch is pressed, Linelock and the 2-step function will

be activated. When the push button is released, Linelock and the 2-step function will be deactivated.

A

B

C

When the LNC-2001 is powered up with no
MAP Sensor installed it will default to
Time Based Retard mode.

+12V

Toggle Switch

Ground

Momentary

Switch

Ground

Linelock

Solenoid

(Arms 2-Step and Linelock)

Fuse

20 Amp

TVS

diode