Enabling the ECM’s tachometer signal output

through EFILive Tune v7.5

9. Double-click on ‘Parameters’ to bring up the window shown in following illustration, which should appear to the right

of the browser window. This calibration is currently set to communicate the tachometer signal via CAN Bus, as shown

by the blue dot on the depressed ‘CAN Bus’ button.

10. In the upper part of the same window, click on the ‘Crank’ button. Pressing this button enables the tachometer signal

output from the ECM. There should now be a blue dot on the depressed ‘Crank’ button, showing that the selection has

been changed.

Page 12 of 17

11. Save the calibration and then flash the new calibration to the vehicle.
12. Since no other device will be connected to the tachometer signal output or the ECM, make sure to enable the pull-up

resistor on the RPM-003.

NOTE: Similar changes will be required if using HP Tuners or any other programming system