beautypg.com

80 appendix, Plm series operation manual rev 1.2.3 – Lab.gruppen PLM 20000Q User Manual

Page 86

background image

80

Appendix

PLM Series Operation Manual rev 1.2.3

PLM 14000

Level

Load

Rated power

Line Current *2)

Watt *1)

Thermal Dissipation

120 VAC

230 VAC

In

Out

Dissipated

BTU/hr

kCal/hr

Standby

12

0

12

42

11

Powered on, idling.

116

0

116

395

100

Amp (I)

Watt

Pink noise (1/8
rated power)

16 Ω / Ch.

1150 x 2

8.5

4.4

603

288

315

1077

271

8 Ω / Ch.

2300 x 2

13.7

7.2

1023

575

448

1529

385

4 Ω / Ch.

4400 x 2

23.4

12.2

1838

1100

738

2518

634

2.67 Ω / Ch.

6200 x 2

30.0

15.7

2410

1550

860

2935

739

2 Ω / Ch.

*4)

7000 x 2

34.0

17.8

2767

1750

1017

3471

874

Pink noise
(max power)
*3)

16 Ω / Ch.

1150 x 2

14.1

7.4

1040

575

465

1588

400

8 Ω / Ch.

2300 x 2

23.7

12.4

1834

1150

684

2334

588

4 Ω / Ch.

4400 x 2

30.0

16.0

2448/2502

1569/1606

879/897

2999/3060

756/771

2.67 Ω / Ch.

6200 x 2

30.0

16.0

2544/2601

1593/1630

951/971

3247/3313

818/835

2 Ω / Ch.

7000 x 2

30.0

16.0

2623/2682

1626/1664

997/1017

3403/3473

857/875

20 kHz
Surveillance
tone

16 Ω / Ch.

1 x 2

2.3

1.2

119

2

117

400

101

Mains connector - 230 V CE version / 230 V ETL version / 115 V ETL version

32 A, Neutrik

@

PowerCon

@

Twist lock

*1) The amplifi er section’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured

and specifi ed here is what is known as the “Active Power” of the amplifi er section providing useful, real-world values of power consumption and heat

dissipation.

*2) Current draw fi gures measured at 230 V. 115 V fi gures are converted from 230 V fi gures.

*3) Figures measured at maximum sustainable power without tripping the mains breaker. Listed separately for 30 A/115 V and 16 A/230 V operation.

Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even

if operation is momentarily in excess of max. ratings.

*4) Italics used for conditions that, if sustained over long time periods, may trigger the mains breaker. Therefore these measurements should not be

used when calculating cooling requirements as they cannot be sustained by the mains breaker over time.

Table 9-3: PLM 14000 Current Draw and Thermal Dissipation

This manual is related to the following products: