Operation and performance 19, 2 high spl profiles – Lab.gruppen PLM 20000Q User Manual
Page 25
Operation and Performance
19
PLM Series Operation Manual rev 1.2.3
5.3.1.2 High SPL Profiles
High SPL profiles do not use the adaptive release time feature. High SPL profiles optimized for high frequen-
cies use less of the look-ahead delay peak-rounding feature; this feature is used most in the Sub profile and
least the HF profile.
▸
Sub - The Sub profile is optimized for frequencies between 20 - 200 Hz
▸
LF - The LF profile is optimized for frequencies between 20 - 1200 Hz
▸
MF - The MF profile is optimized for frequencies between 300 - 6000 Hz
▸
HF - The HF profile is optimized for frequencies above 1 kHz
Table 5-3 shows the theoretical maximum output power for a given load impedance and ISVPL setting.
An ISVPL-to-load calculator that will assist in generating the
appropriate ISVPL setting for a desired power load is available
MAX. SINEWAVE BURST POWER (Watts)
Load Impedance (ohms)
2
2.67
4
8
16
ISVPL SETTING (V
peak)
194
9409
7048
4705
2352
1176
193
9312
6984
4656
2328
1164
181
8190
6143
4095
2048
1024
167
6972
5229
3486
1743
872
153
5852
4389
2926
1463
732
121
3660
2745
1830
915
458
101
2550
1913
1275
638
319
83
1722
1292
861
431
215
70
1225
919
613
306
153
56
784
588
392
196
98
47
552
414
276
138
69
38
361
271
181
90
45
17.8
79
59
40
20
10
Table 5-3: ISVPL-to-output examples
These ratings shown in Table 5-3 are limited by the
CPL (Current Peak Limiter) functions, not by ISVPL
settings, due to power output channel current