beautypg.com

Operation and performance 19, 2 high spl profiles – Lab.gruppen PLM 20000Q User Manual

Page 25

background image

Operation and Performance

19

PLM Series Operation Manual rev 1.2.3

5.3.1.2 High SPL Profiles

High SPL profiles do not use the adaptive release time feature. High SPL profiles optimized for high frequen-
cies use less of the look-ahead delay peak-rounding feature; this feature is used most in the Sub profile and
least the HF profile.

Sub - The Sub profile is optimized for frequencies between 20 - 200 Hz

LF - The LF profile is optimized for frequencies between 20 - 1200 Hz

MF - The MF profile is optimized for frequencies between 300 - 6000 Hz

HF - The HF profile is optimized for frequencies above 1 kHz

Table 5-3 shows the theoretical maximum output power for a given load impedance and ISVPL setting.

An ISVPL-to-load calculator that will assist in generating the

appropriate ISVPL setting for a desired power load is available

at www.labgruppen.com/plm

MAX. SINEWAVE BURST POWER (Watts)

Load Impedance (ohms)

2

2.67

4

8

16

ISVPL SETTING (V

peak)

194

9409

7048

4705

2352

1176

193

9312

6984

4656

2328

1164

181

8190

6143

4095

2048

1024

167

6972

5229

3486

1743

872

153

5852

4389

2926

1463

732

121

3660

2745

1830

915

458

101

2550

1913

1275

638

319

83

1722

1292

861

431

215

70

1225

919

613

306

153

56

784

588

392

196

98

47

552

414

276

138

69

38

361

271

181

90

45

17.8

79

59

40

20

10

Table 5-3: ISVPL-to-output examples

These ratings shown in Table 5-3 are limited by the

CPL (Current Peak Limiter) functions, not by ISVPL

settings, due to power output channel current

capacity.

This manual is related to the following products: