74 appendix – Lab.gruppen PLM 20000Q User Manual
Page 80

74
Appendix
PLM Series Operation Manual rev 1.2.3
Model
Displayed Text
Event Log Text
Category Description
ALL
INPUT MUTE
Input Mute
Mute
The audio signal has been muted at the
input router of the Lake Processor.
ALL
LM PREC. LOW
Speakersafe precision low
Warning
A SpeakerSafe warning indicating insuf-
ficient data to produce reliable results.
This may occur, for example, if a channel
is being driven at a very low level.
ALL
LOAD NOT VER
LoadSmart: Load Not Verified
Warning
A Module containing a Fingerprint has
been loaded, but the load is yet to be
verified with LoadSmart.
20000Q MAINS <65 V
Frame fault: PSU mains <65 V
Fault
Mains input voltage is below 65 Volts
RMS.
20000Q MAINS >270 V
Frame fault: PSU mains >270 V Fault
Mains input voltage is above 270 Volts
RMS.
20000Q MAINS >400 VPK Frame fault: PSU mains >400
VPK
Fault
Mains input voltage is above 400 Volts
Peak.
20000Q MAINS GLITCH
Glitch on mains voltage
detected
Warning
A glitch (missing cycles) on mains input
was detected.
ALL
MOD. IN MUTE
Module Input Mute
Mute
The audio signal has been muted at the
Module input of the Lake processor.
ALL
MOD. OUT MUTE Module Output Mute
Mute
The audio signal has been muted in the
output stage of the Lake processor.
ALL
MODULE CLIP
n/a
Clip
The signal level on the outputs of the
Lake processing module is too high and
is clipping.
ALL
n/a
LoadSmart Verification
Event
LoadSmart load verification is in
progress.
ALL
n/a
Sound Source Changed
Event
The input router has changed sound
source.
20000Q NEED SERVICE:1
Frame fault: Need Service: 1
Fault
Service required, contact your dealer.
20000Q NEED SERVICE:2
Frame fault: Need Service: 2
Fault
Service required, contact your dealer.
20000Q NEED SERVICE:3
Frame fault: Need Service: 3
Fault
Service required, contact your dealer.
20000Q NEED SERVICE:4
Frame fault: Need Service: 4
Fault
Service required, contact your dealer.
20000Q NEED SERVICE:5
Frame fault: Need Service: 5
Fault
Service required, contact your dealer.
20000Q NEED SERVICE:6
Frame fault: Need Service: 6
Fault
Service required, contact your dealer.
20000Q NEED SERVICE:7
Frame fault: Need Service: 7
Fault
Service required, contact your dealer.
20000Q NEED SERVICE:8
Frame fault: Need Service: 8
Fault
Service required, contact your dealer.
ALL
NO INPUT
No Input Source
Fault
The chosen input type has been
deselected or lost and the input type
selector has no alternative input sources
in the priority list.
ALL
NO LOAD
Channel Fault: No Load
Detected
Fault
No load detected at the power output
channel.
ALL
OFFLINE
Frame Offline
Warning
The Lake Controller cannot communicate
with this Lake device.