beautypg.com

Typical flow rate information, Warm-up / stabilization time, Alarms – Heath Consultants Personal Surveyor (PS200 Series) User Manual

Page 88: Display, Power source, Construction, Ip rating, Response times (t90), Flow rate information, Rate, flow

background image

A-2

USER HANDBOOK

TYPICAL FLOW RATE INFORMATION

Pumped Instruments:

Nominal pump flow rate is 0.5 to 0.7
litres per min. Max. 30 metres (97ft.)
sample line

Typical flow fail rate is 0.1 to 0.2
litres per min.

WARM-UP / STABILIZATION TIME

< 40 seconds

ALARMS

Highly visible flashing LED, piercing >90dB audible

DISPLAY

Green / Red LCD backlit display

POWER SOURCE

Lithium Ion rechargeable battery
Runtime > 14 hours (> 8 hours pumped)
Charging time < 4 hours

CONSTRUCTION

High impact rubberized polycarbonate case

IP RATING

IP67

RESPONSE TIMES (T

90

)

LEL = 10 secs. (IEC 60079-29-1)
O

2

= 12 secs. (BSEN 50104)

CO = < 20 secs.
H

2

S = < 20 secs.