Hanna Instruments HI9126 User Manual
Page 2

2
3
GENERAL DESCRIPTION
HI 9126
is a state-of-the-art waterproof, heavy-duty pH meter designed
to provide laboratory results and accuracy under harsh industrial
conditions.
A large multil-level LCD, with clear indications related to the electrode and
instrument status, pH and temperature displayed simultaneously, and
user friendly graphic symbols during calibration.
This meter is provided with a series of new diagnostic features which add
an entirely new dimension to pH measurement, by allowing the user to
dramatically improve the reliability of the measurement:
• 7 memorized buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01
and 12.45) for calibration
• Custom calibration (up to two custom buffers)
• Messages on the LCD to make the calibration easy and accurate
• Diagnostic features to alert the user when the electrode needs cleaning
• Monitoring of the electrode aging
• User-selectable “calibration time-out” to remind you when a new
calibration is necessary
HI 9126
can also measure for Oxidation Reduction Potential in the mV
range with a resolution of 0.1 mV.
It offers an extended temperature range from –20 °C (–4 °F) to 120 °C
(248 °F).
Dear Customer,
Thank you for choosing a Hanna Instruments product.
Please read this instruction manual carefully before using the instrument.
This manual will provide you with the necessary information for correct
use of the instrument, as well as a precise idea of its versatility.
If you need additional technical information, do not hesitate to e-mail
us at [email protected].
Remove the instrument from the packing material and examine it to
make sure that no damage has occurred during shipping.
If there is any damage, notify your dealer or the nearest Hanna
Customer Service Center.
Each meter is supplied with:
• HI 1230B combination double-junction, gel pH electrode
• HI 7662 stainless steel temperature probe with 1 m (3.3’’) cable
• pH 4.01 & pH 7.01 buffer solutions, 20 mL sachet
• HI 700661 electrode cleaning solution
• 100 mL plastic beaker
• 3 x 1.5V AAA Batteries
• Instruction manual
• Rugged carrying case
Note:
Save all packing material until you are sure that the instrument
functions correctly. All defective items must be returned in the
original packing with the supplied accessories.
WARRANTY .................................................................................. 2
PRELIMINARY EXAMINATION ......................................................... 3
GENERAL DESCRIPTION ................................................................. 3
FUNCTIONAL DESCRIPTION ........................................................... 4
SPECIFICATIONS ........................................................................... 5
OPERATIONAL GUIDE .................................................................... 6
pH CALIBRATION ....................................................................... 10
pH BUFFER TEMPERATURE DEPENDENCE ....................................... 15
SETUP MENU ............................................................................. 16
mV CALIBRATION ....................................................................... 18
TEMPERATURE CALIBRATION ....................................................... 18
BATTERIES REPLACEMENT ............................................................ 19
LCD MESSAGE GUIDE .................................................................. 21
TEMPERATURE CORRELATION FOR pH SENSITIVE GLASS ................ 22
ELECTRODE CONDITIONING & MAINTENANCE ................................ 23
TROUBLESHOOTING GUIDE ......................................................... 25
ACCESSORIES ............................................................................. 26
W A R R A N T Y
W A R R A N T Y
W A R R A N T Y
W A R R A N T Y
W A R R A N T Y
HI 9126
is guaranteed for two years against defects in workmanship
and materials when used for their intended purpose and maintained
according to instructions. Electrodes and probes are guaranteed for six
months. This warranty is limited to repair or replacement free of charge.
Damage due to accidents, misuse, tampering or lack of prescribed
maintenance is not covered.
If service is required, contact the dealer from whom you purchased the
instruments. If under warranty, report the model number, date of
purchase, serial number and the nature of the problem. If the repair
is not covered by the warranty, you will be notified of the charges
incurred. If the instruments are to be returned to Hanna Instruments,
first obtain a Returned Goods Authorization number from the Technical
Service department and then send it with shipping costs prepaid.
When shipping any instrument, make sure it is properly packed for
complete protection.
T A B L E O F C O N T E N T S
T A B L E O F C O N T E N T S
T A B L E O F C O N T E N T S
T A B L E O F C O N T E N T S
T A B L E O F C O N T E N T S
P R E L I M I N A R Y E X A M I N A T I O N
P R E L I M I N A R Y E X A M I N A T I O N
P R E L I M I N A R Y E X A M I N A T I O N
P R E L I M I N A R Y E X A M I N A T I O N
P R E L I M I N A R Y E X A M I N A T I O N
G E N E R A L D E S C R I P T I O N
G E N E R A L D E S C R I P T I O N
G E N E R A L D E S C R I P T I O N
G E N E R A L D E S C R I P T I O N
G E N E R A L D E S C R I P T I O N