9

8.0 Troubleshooting

If you are experiencing problems getting the extender to work properly,

please use the following troubleshooting suggestions.

Make sure that all of the connections on both the sender and the

receiver are solid. Loose connections are often the cause of issues.

Try resetting the system by unplugging the power supply connected to

the PSE side, and after 5 seconds, plugging it back in.

Check the state of the LED’s on the front of both the sender and the

receiver. Refer to section 7.1 to interpret the status being indicated.

Make sure the cable length does not exceed the capability of the remote

Receiver. UH-1BT can go a max distance of 70m (229 ft), UH-1BTX

is capable of 100 meters (330 ft), and the UHBX-R-PSE has a mode

switch for 100 meter or 150 meter. (see Receiver User Manual).

Make sure the display is compatible with the video source by

connecting them directly.

Make sure that you are using good quality UTP or STP cables

particularly if the cable distance is approaching the max specifications.

Never use low-skew cable for digital video extension (low skew cables

are suited for analog video extension, but do not work well for digital

video). We recommend 23 Gauge Cat6 cable and if the length is close

to the specified maximum distance, augmented Cat6 is recommended.

The extender requires that the source DDC signals of its HDMI output

operate at100 KHz or less and support clock-stretching. The vast

majority of sources meet these requirements. But if you determine that

a particular source does not (by substituting a video pattern generator,

or a different source), a Hall Research model EMX-HD-AUD is

recommended to resolve source incompatibility issues.

If you still are not able to get the system working properly, contact Hall

Research support (preferably via email or the form on support page of

www.hallresearch .com) with a detailed description of the issue and the

troubleshooting steps you have taken.

Do not open or try to repair the unit yourself as this will void your warranty.

To return the extender for repair, you must contact HR Support at 714-641-

6607 or via email or web. To ship the unit back for repair, make sure to

obtain a Return Material Authorization (RMA) number.