Glow-worm EnergySaverCombi 100 User Manual
Page 8
8
221854B
*
*
*
*
Increase to 25mm clearance from
combustible material.
2.1 Location
The boiler is not suitable for fitting outdoors.
Any electrical switch or boiler control using mains electricity
must be positioned so that it cannot be touched by a person
using a bath or shower.
The boiler must be mounted on a flat wall which is sufficiently
robust to take its weight, refer to Table 2.
2.2 Clearances
The boiler should be positioned so that at least the minimum
operational and servicing clearances are provided, see diagram
2.1.
Additional clearances may be beneficial around the boiler for
installation and servicing.
For flue installations where external access is not practicable,
consideration should be given for the space required to insert
the flue internally which may necessitate clearance larger than
those specified in diagram 2.1.
Diagram 2.1
9070
5
5
200
† 600
5
5
25
200
MINIMUM CLEARANCE FROM
PERMANENT SURFACES
† A removable compartment door can be
placed at least 5mm in front of the appliance.
2 Boiler Position
Dimensions in millimetres