beautypg.com

Instructions for use – Glow-worm Miami 4 User Manual

Page 4

background image

4

221904D

Diagram 3

9460

Diagram 4

CONTROL
THERMISTOR
KNOB 'A'

Instructions for Use

Clearance

A shelf or surround of a maximum depth of 150mm may be
fitted, provided that clearances above and at the sides of the fire
front are as shown in diagram 1. For a shelf made from wood or
other combustible materials deeper than 150mm add 12.5mm
for every 25mm of shelf depth over 150mm.

On no account must a carpet or other combustible material be
laid directly under the fire, unless the minimum clearances
shown in diagram 2, is achieved.

The dimension is taken from the bottom of the fire case to the
top of the carpet pile or other floor covering.

Hearth

A fire proof hearth under the fire front must have the minimum
dimensions as shown in diagram 3.

Diagram 2

9458

RESET
POSITION

RESET NEON
(RED)

BURNER ON
NEON (GREEN)

710mm

300mm

50mm

13mm NON-COMBUSTIBLE

MATERIAL

CARPET OR COMBUSTIBLE
MATERIAL CLEARANCE

Diagram 1

9459

75mm

75mm

FROM NON-COMBUSTIBLE MATERIAL

150mm

50mm

MIAMI ILLUSTRATED

MINIMUM HEARTH DIMENSIONS

9918

BOILER USER CONTROL

MINIMUM

MAXIMUM

OPERATING YOUR BOILER AND FIRE

Safety Device

BOILER - This appliance is fitted with a flue blockage safety
device which will shut down the appliance in the event of
abnormal flue conditions. This device is NOT a substitute for an
independently mounted Carbon Monoxide detector.

FIRE FRONT- The fire is fitted with a safety device which will
shut it down if there is a lack of oxygen it also incorporates a
probe which senses that the heat from the pilot flame is correct.
If the probe is cool, the device will prevent any gas flow unless
the control knob is held down at the ignition position.

If, for any reason, the flames go out when the fire is hot or if the
fire is turned off when hot, always wait at least three minutes
before attempting to relight.

If the boiler and/or fire shuts down frequently for no apparent
reason the first things to be checked are the chimney and air
inlets into the room.

Any problems found must be put right, by a competent person,
before the appliance is used again.

50mm