5 Installation
5.2 Gas Supply Connection
Connect and tighten the union nut at the fire front isolating valve,
see diagram 5.4.
Refit floor protection plate if removed.
Turn gas on at the fire isolating valve by removing cap and
turning restrictor screw anti-clockwise.
Pressure check the installation pipework for gas soundness. In
the United Kingdom check in accordance with the current
edition of BS6891. In the Republic of Ireland check in accordance
with the rules in force.
5.3 Boiler User Control
Place the boiler user control in position from the inside to the
aperture on the bottom of the R/H louvre of the fire chassis,
making sure that it is the correct way up, see diagram 5.5.
Secure from the outside to the louvre with the screws, from
fittings pack, see diagram 5.5.
5.4 Radiants Installation
Remove radiants from packaging and fit as described in
"Replacing Radiants" in the Instructions for Use section of these
instructions.
Diagram 5.3
DOG POINT SCREWS
9474
Diagram 5.5
UNION
NUT
GAS FIRE
FEED PIPE
Diagram 5.4
9480
SECURING
SCREWS (2)
DOG POINT
SCREW (2)
TOP FIXING
BOTTOM FIXING
9478
FIRE
ISOLATING
VALVE
BOILER USER
CONTROL
LOUVRE
ASSEMBLY
LOUVRE
ASSEMBLY
FLOOR
PROTECTION
PLATE