beautypg.com

10 fault finding – Glow-worm Miami 4 User Manual

Page 17

background image

17

221904D

10 Fault Finding

10.1 Fire Font Ignition

Remove casing as section 9.

Refer to Fire Front Ignition Fault Finding, diagram 10.1.

Diagram 10.1

FIRE FRONT IGNITION FAULT FINDING

9631

10.2 Flue Blockage Safety Device

If the device operates it indicates there could be a problem with
the chimney. First make sure air vents are free of obstructions,
by carrying out spillage checks as section 7.

START HERE

Fire will not light

Turn off appliance tap; turn
on appliance tap and
observe spark

Spark
across gap,
ignition

No spark
across
gap

Spark
no
ignition

Using a match, ensure correct
functioning of burner in
all setting positions. Check that
electrode and piezo unit connections
are satisfactory. Check that
burner pressure is as specified.
Correct any fault found.

Spark
across gap,
ignition

No spark
across
gap

Spark
no
ignition

Ensure gap is within specified
tolerance, refer to SERVICING
Turn tap to energise igniter

Disconnect ignition lead from
electrode, place connector
within 4mm of burner and
operate piezo

Spark
across gap,
ignition

Spark
no
ignition

Replace pilot assembly and
reassemble ignition system

Spark
across gap,
ignition

Spark
no
ignition

Ensure gap is within specified
tolerance. Turn tap to energise
igniter

Spark
across gap,
ignition

Spark
no
ignition

Remove ignition lead from piezo unit
and place screwdriver between
appliance chassis earth and piezo
unit, leaving 4mm gap between blade
and spade connector.
Operate igniter.

Spark
across
gap

No spark
across
gap

Renew ignition lead and
reassemble ignition system

Spark
across gap,
ignition

Spark
no
ignition

Change piezo unit and
reassemble ignition system

Spark
across gap
ignition

Check several times that
ignition is satisfactory

END