Directed Electronics MAXX3 User Manual
Page 27
®2002 Directed Electronics, Inc.
27
Factory No. of
Feature
Setting
Chirps
Secondary Action
Arm/Disarm/Panic
Button
20
Press any remote button(s). The
Two Stage Unlock
Channel 1
siren will chirp once for confirmation.
Accessory(-) Output
Button
21
Press any remote button(s). The
for Boot Release
Channel 2
siren will chirp twice for confirmation.
(disarmed only)
Silent Arm / Disarm
Button
22
Press any remote button(s). The siren
Channel 3
will chirp three times for confirmation.
Accessory(-) Button
23
Press any remote button(s). The siren
Output Timed
Channel 4
will chirp four times for confirmation.
Accessory(-) Output
Button
24
Press any remote button(s). The siren
Pulsed / Latched
+
Channel 5
will chirp five times for confirmation.
Remote Sensor
Button
25
Press any remote button(s). The siren
Bypass
+ Channel
6
will chirp 6 times for confirmation.
All Channel Learn
—
26
Press
button. The siren will
chirp once to confirm factory preset
order.
Instant Code Deletion
—
27
Wait 3 seconds. The siren will chirp
twice. All remotes are erased from
memory.
NOTE: When assigning channels to different buttons than the factory
settings, you must “All Channel Learn” a transmitter and then change the
individual assignments with feature number 20 to 25 as required.