5.0 Maintenance of the EX-5100

C

AUTION

:

Do not open the

EX

-

5100

S/T

in a classified area.

C

AUTION

:

Do Not Attempt A Span Procedure Without Calibration Gas Applied to The Sensor; if this is done, the S/T is forced

into a calibration fault mode.

Magnetic switches control the

M

ENU

and

S

ELECT

functions. The

M

ENU

and

S

ELECT

switch locations are indicated on the

display panel, see Figure 3. The

M

ENU

switch is used to display the various menu options and make incremental changes to

numbers such as alarm points, calibrations gas, etc. The

S

ELECT

switch is used to select that option or entered digit. Most

maintenance functions are controlled by simple taps of the supplied magnet on the transmitter glass, below the

M

ENU

and

S

ELECT

boxes on the front panel.

5.1 Maintenance Menu

To enter the maintenance menu hold the magnet over the

M

ENU

switch for 2 to 4 seconds

Table 1 indicates the maintenance menu sequence see Figure 5 for a detailed maintenance menu flow chart.

Table 1: EX-5100 maintenance Menus Sequence

Example of Display

Function

Normal Display Mode

Measurement of target gas

Hold the magnet over

M

ENU

switch for 2 – 5 seconds to enter the Maintenance Menu

The Power/Fault LED will flash Green – Red to indicate the

EX-5100

is in Maintenance Mode

To exit the maintenance Menu and return to the Normal
Display Mode:

If intended function Tap the magnet over

S

ELECT

switch

Tap the magnet over the

M

ENU

switch to advance to the Zero procedure

For adjusting Zero:
If intended function Tap the magnet over

S

ELECT

switch

Tap the magnet over the

M

ENU

switch to advance to the Span procedure

For adjusting the Span:
If intended function Tap the magnet over

S

ELECT

switch

Tap the magnet over the

M

ENU

switch to advance to each Alarm set point procedures

For adjusting the Alarm 1, 2 and 3 set points:
If Intended function Tap the magnet over

S

ELECT

switch

Tap the magnet over the

M

ENU

switch to advance the mA Span set point procedure

For adjusting the mA Span set point:
If intended function Tap the magnet over

S

ELECT

switch

Taping the

M

ENU

switch without taping the

S

ELECT

switch will allow you to cycle through the menu options.

You must Tap the

S

ELECT

switch win order to change the desired operation.

N

OTE

:

If the S/T fails to respond, the magnet may have become weak and may need to be replaced.