beautypg.com

EarthQuake MC43ES User Manual

Page 19

background image

Operator’s Manual

800 Watt Inverter Generator

Check for parts online at

www.getearthquake.com or call 800-345-6007 M-F 8-5

19

TROUBLESHOOTING GUIDE

PROBLEM

POSSIBLE CAUSE

REMEDY/ACTION

Engine will not start

1. Engine switch in STOP position

1. Flip engine switch to ON position

2. Out of fuel

2. Refuel

3. Fuel valve in OFF position

3. Turn fuel valve to ON position

4. Spark plug wire disconnected

4. Connect spark plug wire to spark plug

5. Spark plug wet, faulty or improperly gapped

5. Clean, replace or gap spark plug

6. Economy switch in ON position

6. Flip economy switch to the OFF position; Once

generator is running flip to the ON position

7. Fuel tank cap air vent in CLOSED position

7. Turn to OPEN position

Engine starts, then

runs rough

1. Dirty air filter

1. Clean or replace air filter

2. Choke partially engaged

2. Turn off choke

3. Defective or dirty spark plug

3. Clean or replace spark plug

4. Economy switch is defective

4. Replace economy switch

5. Carburetor out of adjustment

5. Call Earthquake Customer Service

Engine is hard to start

1. Stale fuel

1. Drain old fuel and replace with fresh. Use fuel

stabilizer at end of season

2. Spark plug wire loose

2. Make sure spark wire is securely attached to spark

plug

3. Dirty carburetor

3. Clean carburetor, use fuel stabilizer, new fuel can

Engine misses or lacks

power

1. Clogged fuel tank

1. Remove and clean fuel tank

2. Clogged air filter

2. Clean or replace air filter

3. Carburetor out of adjustment or bad

3. Call Earthquake Customer Service

4. Spark plug wet, faulty or improperly gapped

4. Clean, replace or gap spark plug

Engine runs, then

quits

1. Fuel tank cap air vent in CLOSED position

1. Turn to OPEN position

2. Low fuel level

2. Add fuel to tank

3. Incorrect engine oil level

3. Check engine oil level, add or drain as needed

4. Contaminated fuel

4. Remove and replace contaminated fuel; Clean or

replace fuel strainer

5. Defective low oil level switch

5. Replace low oil level switch

6. Defective ignition coil

6. Replace ignition coil

Engine revs too high

1. Carburetor out of adjustment

1. Call Earthquake Customer Service

Engine speed increases and decreases, this is normal as the generator starts up and as loads vary.
Contact Earthquake customer service at 800-345-6007 if additional assistance is needed.

This manual is related to the following products: